Cisco Headend System Release 2.7 User Guide

Page of 118
 
Chapter 2    Provisioning SDV Services on the DNCS 
 
 
 
20 
4024447 Rev C 
7  Do you need to create an additional SDV server or backup SDV server? 
 
If yes, click the SDV Server List link from the top area of the window and 
then repeat steps 3 through 6. 
 
If no, click Exit to close the Switched Digital Video (SDV) Server List 
window. 
 
Provisioning Alarms for an SDV Server 
Important: You must set the Alarm Threshold for Alarm ID 6 and Alarm ID 100 to 1 
as they directly relate to the Resource Fail Threshold and the Resource Alarm 
Threshold values defined for the SDV Server software. For details about the SDV 
Server software, refer to the Series D9500 Switched Digital Video Servers Installation and 
Operation Guide
 (part number 4012584). 
When provisioning alarms for an SDV server, you can define the severity of an 
alarm level (for example, a major alarm or a critical alarm), as well as the maximum 
number of instances an event can occur until an alarm situation exists. This section 
describes how to provision specific SDV alarms for an SDV server. 
1  From the SDV Server List window, click Alarm Provisioning. The SDV Server 
Alarm Provisioning window opens and describes each alarm type by an ID 
number and a description.