Cisco Headend System Release 2.5 Maintenance Manual

Page of 202
 
Chapter 1    Staging Preparation 
 
 
 
24 
4024836 Rev D 
Notes: 
– 
Negative values are not permitted in this field. 
– 
If you define a value greater than 2, be aware of the following issues: 
 
The podData file on the BFS can contain no more than 1500 entries. 
During staging, a pod (CableCARD)/host pair is added to the 
podData file for the amount of time defined in this field. When the 
Authorization Time-out Period is reached, the pod/host pair is 
removed from the file. 
 
If you attempt to exceed 1500 entries during the time-out period that 
you have defined, pod/host pairs will not be able to bind. 
 
Deauthorization Time-Out Period—Enter the length of time (in days) the 
Authorization message is kept in the file on the BFS. Enter 30 in this field. 
 
Max Key Session Period—Enter the rate that the copy protection key should 
change. The rate referenced depends on the communications mode of the 
CableCARD module, as determined by the host's capabilities: 
– 
Multistream Mode (MMode): The field represents minutes. Therefore, 
entering a 1 in this field causes the copy protection key to change every 
minute. Enter 10 in this field. 
– 
Singlestream Mode (SMode): The field represents decaseconds. 
Therefore, entering a 1 in this field causes the copy protection key to 
change every 10 seconds. Enter 10 in this field.  
Important: Defining a rate less than 1 minute (for MMode) or 10 decaseconds 
(for SMode) requires a large number of unnecessary calculations on the 
CableCARD. Defining a rate greater than X minutes (for MMode) or 20 
decaseconds (for SMode) does not coincide with best security practices. 
 
Maximum Host Change Count Allowed—Enter the maximum number of 
times that a CableCARD module is allowed to autobind with a different host. 
When a module exceeds this limit, it is no longer allowed to autobind with a 
different host. 
Note: The default setting of 99 allows an unlimited number of autobindings. 
 
RF Output—Select the channel to which the CableCARD module outputs 
video. Typically, you should select the same channel that the DHCTs use for 
the CableCARD modules. 
 
Card Authorization Phone Number—Enter the telephone number that 
subscribers call to verify that their CableCARD module was authorized. You 
can enter up to 20 alphanumeric characters, including spaces, in this field. 
 
Maximum Bindings Within Authorization Time-Out Period—Enter the 
maximum number of CableCARD modules and DHCTs that can bind during 
a staging period. We recommend that you set this field to the maximum 
setting of 1500