Cisco Model 6944 and 6940 Node bdr Dig Rev 2 1 Mux System for Prisma II Data Sheet

Page of 8
Prisma II bdr Digital Reverse 2:1 Dual Multiplexing System 
for High Density Installations 
 
5
 
 
Link Performance 
 
General 
Units 
 
Notes 
Bandpass MHz 
5-42 
 
Full Scale Single CW Carrier Amplitude 
dBmV 
54 
1,2,3 
Noise Floor Amplitude 
dBmV/Hz 
-85 
1,3 
Link Gain (minimum) 
dB 
17 
3,4,5 
Response Flatness 
dB 
± 0.5 
 
 
 
 
 
 
 
Notes: 
1.  With respect to the input port on 2:1 Transmit Processor. 
2.  A CW carrier of this amplitude applied to the RF input will exercise the full-scale range of the A/D converter.  Full scale is 
analogous to 100% OMI for Analog Lasers. 
3.  Variable Attenuator on 2:1 Transmit Processor set to 0 dB. 
4.  Variable Gain Control on 2:1 Receive Processor set to 0 dB. 
5.  Add Link Gain (dB) to Transmit Processor RF input level to determine Receive Processor RF output level. 
Noise Power Ratio (NPR) Performance
25
30
35
40
45
50
55
-60
-55
-50
-45
-40
-35
-30
-25
Transmit Processor Input Power per Hz (dBmV/Hz)
NPR (
d
B)
(Applies to Constant Power / Hz Loading over 35 MHz band)
 
NPR Notes: 
1.  Input power is specified with respect to the input port of the Transmit Processor module. 
2.  Variable Attenuator on 2:1 Transmit Processor set to 0 dB and Variable Gain Control on 2:1 Receive Processor set to 0 dB. 
 
 
 
 
Note: 
Unless otherwise stated, all link performance specifications shown reflect minimum performance over the specified operating temperature 
range. 
20
25
40
5
Delay
20 ns/division
Frequency (MHz)
10
15
30
35
42
Group Delay