Cisco Headend System Release 2.5 User Guide

Page of 52
 
 
Staging Tuning Adapters 
4025012 Rev B 
15 
 
Staging Tuning Adapters 
Follow these steps to stage Tuning Adapters. 
1  Scan the Tuning Adapters into the billing system using the appropriate 
procedures authorized by your billing system vendor. 
Important: Ensure that the billing system operator does not send transactions to 
the DNCS at this time. 
2  Unpack the Tuning Adapters you want to stage. 
3  Place the Tuning Adapters on the staging rack. 
4  Connect the CABLE IN port to an RF signal. 
5  Connect the Tuning Adapters to AC power. Each Tuning Adapter downloads 
the required software from the DNCS.  
6  Wait for the Tuning Adapters to indicate that the download is complete. The 
POWER LED will light for two seconds, go off for one second, then light for two 
seconds before each Tuning Adapter reboots. 
7  Once the Tuning Adapter reboots, send a "hit" to the DNCS from the billing 
system to place the Tuning Adapters in service with at least one package. Wait 
for the Tuning Adapters to show the correct indication (either the Brick mode 
indicator or a steady-on LED). 
8  Connect the CABLE OUT port on each Tuning Adapter to a properly staged 
UDCP device. 
9  Connect the UDCP device to a TV monitor and verify authorized channels. 
10  Does your business process require inventory Tuning Adapters to be authorized 
for service? 
 
If yes, go to step 11. 
 
If no, downgrade (disable) the Tuning Adapters in accordance with your site 
process, wait for the Brick mode indicator or loss of channel tuning 
information for SDV channel change requests. 
11  Disconnect the Tuning Adapters and either return them as staged inventory to 
your warehouse or give them to technicians to install at the subscribers' 
locations.