SARA Server 3.1.6 Installation Instructions 
4019300 Rev B 
Verify Key Parameters in the onconfig File 
Introduction 
After you run the Doctor Report, verify that the TAPEDEV and LTAPEDEV 
parameters are set correctly in the onconfig file. If these parameters are set 
incorrectly, you may encounter difficulties during the installation. 
How Long Does It Take? 
On a typical system, it takes about 1 minute to determine the current settings of the 
TAPEDEV and LTAPEDEV parameters and about 5 minutes to change the settings. 
Verify TAPEDEV and LTAPEDEV Parameters 
Complete these steps to verify that the TAPEDEV and LTAPEDEV parameters are 
set correctly. 
1. 
On the DNCS, open an xterm window. 
2. 
Type cd /export/home/informix/etc and press Enter
Result:  The system makes /export/home/Informix/etc the working 
directory. 
3. 
Type grep –i tapedev onconfig and press Enter
Result:  The system searches the onconfig file and displays lines that contain 
“tapedev,” similar to the example shown here.  
 
4. 
Did the system display /dev/null as the tape device path and log tape device 
path? 
• 
If yes, the TAPEDEV and LTAPEDEV parameters are set correctly. Go to 
step 9. 
• 
If no, go to step 5.