Cisco Model D-PCG1000 PowerKEY CAS Gateway Technical References

Page of 10
 
78-4021637-01 Rev B 
 
Configure Stat Mux Dejitter Groups 
 
Configuring Stat Mux Dejitter Groups 
Complete these instructions to set up SMDGs by mapping the input port that 
receives the multiplexed source to the output port that modulates the source onto 
the network. 
1  From the DNCS Administrative Console, select the Network Element 
Provisioning tab. 
2  Click QAM. The QAM List window opens. 
3  Double-click the GQAM modulator on which you want to set up an SMDG. The 
Set Up GQAM window opens with the Basic Parameters tab in the forefront. 
4  Click the Advanced Parameters tab.  
5  Click the Set Up button for Stat Mux Dejitter Groups. The Stat Mux Dejitter 
Groups window opens for the selected GQAM modulator. 
6  Click New
7  Enter the following information to map the input port that receives the 
multiplexed source to the output port that modulates the source onto the 
network: 
 
ID - Enter an identifier to indicate the SMDG.  
Notes: 
– 
This must be a unique numerical value from 1 to 65535.  
– 
This number must be unique across all of the GQAMs in your system. 
 
Bandwidth - Not selectable; the bandwidth defaults to the bandwidth of the 
GQAM RF port being used for the SMDG. 
 
Input Port - Select the input port type (ASI or Ethernet) that this SMDG uses. 
 
Destination IP Address - If a GbE port receives the multicast source, enter 
the IP multicast address for the GQAM modulator.  
Notes: 
– 
This is only used for multicast sessions. If you are not using multicast 
sessions, leave this field blank. 
– 
If an ASI port receives the source, leave this field blank. 
 
Destination UDP Port - If a GbE port receives the unicast source, enter the 
UDP port on the GQAM modulator that receives the multiplexed source. 
Notes: 
– 
This is only used for unicast (non-multicast) sessions. If you are using 
multicast sessions, leave this field blank. 
– 
If an ASI port receives the source, leave this field blank. 
 
Output Port - Select the output port that this SMDG uses. 
8  Click Save. Parameters for the SMDG are listed in the Stat Mux Dejitter Group 
window.