Cisco Cisco RF Gateway 1

Page of 286
 
 
 
Monitoring the RF Gateway 1 
 
78-4025112-01 Rev H0 
61 
 
Once the PID conflict is resolved at the headend device, then after refreshing the 
session, the PID conflict alarm will be cleared. The state in the Input Monitor page 
will also change to Active only after the session refresh is completed. Even if the 
input PID conflict is resolved, but the session refresh button is not clicked, then state 
in Input monitor page will remain as "Input PID conflict" 
 
Data Monitoring 
The Data Monitoring page provides information related to how data streams on the 
input are bound to QAM resources on the input. The following illustration shows 
the Data Monitoring screen. 
 
Parameters 
The following table explains the Data parameters. 
Parameter 
Description  
Output Channel 
The output channel for a data stream. 
Type 
Type of data stream (DOCSIS MPT with UDP, DOCSIS MPT 
without UDP, DOCSIS PSP with UDP, DOCSIS PSP without 
UDP, MPEG, DATA). 
GbE Input 
GbE input associated with the data stream. 
Output Bitrate 
Bitrate of the data stream. 
Destination IP 
Destination IP of the data stream. 
UDP/DEPI 
Destination UDP or DEPI session ID for the data stream. 
Status 
Status of the data stream (Stream Active, Stream Inactive).