4034994 Rev B                                                                                    ix                                           
Important Safety Instructions, Continued 
If the plug still fails to fit, contact an electrician to replace the obsolete 2-terminal 
outlet. 
Grounding Terminal 
If this equipment is equipped with an external grounding terminal, attach one end of 
an 18-gauge wire (or larger) to the grounding terminal; then, attach the other end of 
the wire to a ground, such as a grounded equipment rack. 
Safety Plugs (European Union) 
 
Class I Mains Powered Equipment   
Provided with a 3-terminal AC inlet and requires connection to a 3-terminal mains 
supply outlet via a 3-terminal power cord for proper connection to the protective 
ground. 
Note: The equipotential bonding terminal provided on some equipment is not 
designed to function as a protective ground connection. 
Class II Mains Powered Equipment 
Provided with a 2-terminal AC inlet that may be connected by a 2-terminal power 
cord to the mains supply outlet. No connection to the protective ground is required 
as this class of equipment is provided with double or reinforced and/or 
supplementary insulation in addition to the basic insulation provided in Class I 
equipment. 
Note:  Class II equipment, which is subject to EN 50083-1, is provided with a chassis 
mounted equipotential bonding terminal. See the section titled Equipotential 
Bonding for connection instructions. 
Equipotential Bonding 
If this equipment is equipped with an external chassis terminal marked with the IEC 
60417-5020 chassis icon (
), the installer should refer to CENELEC standard EN 
50083-1 or IEC standard IEC 60728-11 for correct equipotential bonding connection 
instructions. 
 