Important Safety Instructions, Continued
If the plug still fails to fit, contact an electrician to replace the obsolete 2-terminal
outlet.
outlet.
Grounding Terminal
If this equipment is equipped with an external grounding terminal, attach one end of
an 18-gauge wire (or larger) to the grounding terminal; then, attach the other end of
the wire to a ground, such as a grounded equipment rack.
an 18-gauge wire (or larger) to the grounding terminal; then, attach the other end of
the wire to a ground, such as a grounded equipment rack.
Safety Plugs (European Union)
Class I Mains Powered Equipment
Provided with a 3-terminal AC inlet and requires connection to a 3-terminal mains
supply outlet via a 3-terminal power cord for proper connection to the protective
ground.
Note: The equipotential bonding terminal provided on some equipment is not
designed to function as a protective ground connection.
supply outlet via a 3-terminal power cord for proper connection to the protective
ground.
Note: The equipotential bonding terminal provided on some equipment is not
designed to function as a protective ground connection.
Class II Mains Powered Equipment
Provided with a 2-terminal AC inlet that may be connected by a 2-terminal power
cord to the mains supply outlet. No connection to the protective ground is required
as this class of equipment is provided with double or reinforced and/or
supplementary insulation in addition to the basic insulation provided in Class I
equipment.
Note: Class II equipment, which is subject to EN 50083-1, is provided with a chassis
mounted equipotential bonding terminal. See the section titled Equipotential
Bonding for connection instructions.
cord to the mains supply outlet. No connection to the protective ground is required
as this class of equipment is provided with double or reinforced and/or
supplementary insulation in addition to the basic insulation provided in Class I
equipment.
Note: Class II equipment, which is subject to EN 50083-1, is provided with a chassis
mounted equipotential bonding terminal. See the section titled Equipotential
Bonding for connection instructions.
Equipotential Bonding
If this equipment is equipped with an external chassis terminal marked with the IEC
60417-5020 chassis icon (
60417-5020 chassis icon (
), the installer should refer to CENELEC standard EN
50083-1 or IEC standard IEC 60728-11 for correct equipotential bonding connection
instructions.
instructions.