Upgrading the Amplifier to a Node, Continued 
To Install the GainStar Node Lid   
Follow these steps to install the GainStar Node Lid. See illustration below. 
Attach the GainStar Node lid and insert the hinge locking pin. 
Insert the Power adapter in the power in/out port. 
Insert the diplexer filter adapter in the Diplexer Filter port. 
Insert the interface connector in the port. 
Change the Fwd input EQ and Fwd output EQs to Linear EQs. (Fwd input 
Linear EQ should be ordered by the customer) 
Change the interstage PAD from 0 dB to 2 dB (862MHz) or 1 dB to 3 dB 
(1GHz). 
Important: For more information, refer to the GainStar Node Installation and 
Operation Guide, part Number 4035006.