Cisco Model D9479 Gigabit QAM Modulator Installation Guide

Page of 134
 
 
Install the Modulator Into a Rack 
78-745431-01 Rev E 
23 
 
 
 
Environmental Requirements Table 
 
Item 
Specification 
Operating Temperature 
0° to 50°C (32° to 122°F) 
  CAUTION: 
Avoid damage to this product! Your warranty is 
void if you operate this product above the 
maximum specified operating temperature. 
Use caution when installing wiring and racks to 
avoid obstruction of air flow into the side air 
vents of the GQAM, or out of the vent fans at the 
GQAM side panel
Important: You must use the supplied notched rack 
mounts (part numbers 734845 and 734846) to mount the 
GQAM in the rack. These rack mounts allow correct air 
circulation through the unit. 
Storage Temperature Range 
–10° to 70°C (14° to 158°F) 
Operating Humidity 
5 to 95%, non-condensing 
Vibration Susceptibility 
No data errors with a chassis vibration of 0.5 Gs. No data 
errors with a vibration frequency of 10 to 400 Hz 
Electrostatic Shock Susceptibility  No damage sustained from five discharges of 15 KV IEC 
electrostatic discharge model (150pF + 150 Ω) to all 
exposed connections 
 
 
Installing the Modulator into a Rack 
 
 
CAUTION: 
Do not tangle or strain interconnecting cables. 
Use caution when installing wiring and racks to avoid obstruction of airflow 
into the side air vents of the GQAM or out of the vent fans on the side of the 
GQAM. 
IMPORTANT: You must use the supplied notched rack mounts to provide 
additional support and to allow correct air circulation through the unit. 
 
1  Install the rack mounts. 
Important: The supplied rack mounts (part numbers 734845 and 734846) must be 
used. When you use the supplied rack mounts, you can install these modulators 
above or below each other in the rack with no space required. These rack mounts 
provide additional support along with the following features: 
 
Attaches directly to the rack