Cisco Cisco Prisma II EDR Receiver Installation Guide

Page of 162
 
Chapter 3        Operation using ICIM 
 
 
 
66 
 
ALARMS Menus 
When a module ALARMS menu is selected, press the 
  key or the 
  key 
to scroll through alarms. Some typical ALARMS menus are shown below. 
A L A R M S
A L A R M S
S h e l f
5
S l o t               1 2
S h e l f
5
S l o t               1 2
P 2 - E D R - R X
O p t P i n 1
F a u l t
P 2 - E D R - R X
O p t P i n 2
F a u l t
A L A R M S
S h e l f
5
S l o t               1 2
P 2 - E D R - R X
R x 1 _ D a t a
F a u l t
A L A R M S
S h e l f
5
S l o t               1 2
P 2 - E D R - R X
R x 2 _ D a t a
F a u l t
 
Note: For details on all alarm parameters, see Module Parameter Descriptions (on 
page 109). 
 
To Set Adjustable Alarm Thresholds using the ICIM 
You can use the ICIM to change the adjustable alarm thresholds of this module from 
their factory default values. 
1  At the MODULE menu, press the 
  key. The STATUS menu appears on the 
ICIM LCD. 
2  Press the 
  key. The alarm thresholds previously set are displayed. If the 
label n/a is displayed, you cannot configure that alarm threshold. Press the 
 
key to highlight the alarm threshold for the next parameter. 
3  When the threshold that you wish to set is highlighted, press the 
  key. 
4  Press the 
  key or the 
  key to change the increment size. 
5  Press the 
  key or the 
  key to adjust the alarm threshold. 
Note: Press the Cancel ( 
  ) key to return to the previous menu. 
6  Press the 
  key to save the changes. The message Data Saved appears on 
the ICIM LCD. 
7  When finished, press the 
  key to return to the MAIN menu.