Cisco Cisco Prisma II EDR Receiver Data Sheet
Prisma II XD Platform
2
XD Chassis
Prisma II XD Chassis
• Very high usable module density (up to 16 modules per 3 RU chassis)
• Compatible with all Prisma II high density (HD) modules
• DC power can be connected directly to the chassis without the need of
a power supply module
• Low power consumption
• Broad operating temperature range
• Integrated front side fiber trough and rear-to-front access conduit for
easy fiber management
• Front access local craft port for convenient setup
• Rear access contact closure block
Specifications
Electrical
Units
Notes
Connections:
- SNMP compatible ICIM
- Local Alarm
- Auxiliary Power Input (-48 V DC)
- Ground Stud (Rear)
- SNMP compatible ICIM
- Local Alarm
- Auxiliary Power Input (-48 V DC)
- Ground Stud (Rear)
RJ45
Terminal Block
Molex 03-12-1036
#10-32 thread
DC Input Voltage Range
V DC
-40 to -60
DC Power Consumption (max)
W DC
185
5
AC Power Consumption (max)
W AC
220
4,5
Bandwidth
MHz
5 – 1002
Environmental
Units
Notes
Operating Temperature Range
°C
°F
0 to +50
+32 to +122
1,2
Storage Temperature Range
°C
°F
-40 to +70
-40 to +158
Humidity Range
%
0 to 95
3
Altitude Range
ft.
-200 to +6561
(above sea level)
Physical Dimensions
Units
Notes
D x W x H
in.
cm
22 x 17.5 x 5.25
55.9 x 44.5 x 13.3
Weight lb
kg
25
11.3
Rack Units
RU
3
Notes:
1.
1.
Air temperature measured at the air inlet of the Prisma II XD chassis.
2.
All unused slots in the Prisma II XD chassis need to be filled with a Module Blank for proper system cooling.
3.
Recommended for use only in non-condensing environments.
4.
With optional AC power supply.
5.
For fully-loaded chassis.
Ordering Information
Description
Part Number
Prisma II XD Chassis, F connector
4022058
Prisma II XD Chassis, F connector, with ICIM
4023768
Prisma II XD Chassis, Blank Module
4023066
Prisma II XD Chassis, DC Interconnect Cable
4023718
Prisma II XD Chassis, DC Power Extension Cable
4011730
Prisma II XD Chassis, Fan Tray Assembly
4031617