Cisco Prisma II 1310 nm HDTx Transmitters Installation Guide

Page of 142
 
 
Connecting the ICIM to Additional Chassis 
78-4009700-01 Rev E 
27 
 
Connecting the ICIM to Additional Chassis 
Chassis-to-Chassis ICIM Connections 
The Prisma II platform allows the ICIM to be located in one chassis and control 
modules located in several other chassis. This communication “daisy-chain” can be 
enabled by connecting cables to the ICIM IN and ICIM OUT connectors located on 
the connector interface panel of the chassis. This connection is required if an ICIM in 
one chassis is to communicate with or control any module located in a separate 
chassis. 
Note: An ICIM can control a maximum of 140 modules. Depending on your 
application, this is typically 6 or 7 chassis to a rack. Do not exceed these limits. 
 
ICIM IN and ICIM OUT Connectors 
Every Prisma II Standard and II XD Chassis has a DB9 ICIM IN and a DB9 ICIM 
OUT connector for the purpose of chassis-to-chassis ICIM connections. ICIM IN is a 
female connector and ICIM OUT is a male connector. 
Standard Prisma II Chassis 
 
Prisma II XD Chassis 
 
 
ICIM IN and ICIM OUT Cables 
The cable required for both ICIM IN and ICIM OUT connections is a shielded 9-
wire serial extension cable, DB9 Female to DB9 Male. This cable can be purchased 
locally or from the factory. The chassis data sheet lists the part number for a 6-foot 
DB9 Female to DB9 Male serial extension cable. The connectors are a serial 9-pin D-
shell (EIA 574/232).