Cisco Prisma II 1310 nm HDTx Transmitters Installation Guide

Page of 142
 
Chapter 2    Module Installation 
 
 
 
28 
78-4009700-01 Rev E 
To Connect Chassis-to-Chassis ICIM IN and ICIM OUT Ports 
1  Connect the serial extension cable from the ICIM OUT of the chassis containing 
the ICIM to the ICIM IN connector of the second chassis. 
2  Connect a serial extension cable from the ICIM OUT of the second chassis to the 
ICIM IN of the third chassis. 
3  Continue this “daisy-chain” connection until all chassis are connected. 
4  Connect an ICIM OUT terminator, part number 4013014, to the ICIM OUT 
connector on the last chassis in the daisy-chain connection. The ICIM OUT 
terminator ships with the ICIM. 
Important: 
 
All chassis connected in the daisy-chain must be powered and have a fan tray 
installed. A chassis connected in the daisy-chain that is not powered or has no 
fan tray installed will cause faulty operation of the ICIM. 
 
All chassis connected in this daisy-chain must have a unique chassis ID number. 
 
If the ICIM OUT terminator that ships with the ICIM is not installed on the last 
chassis of a daisy-chain connection, faulty communication with the ICIM may 
occur.