Cisco Cisco Prisma II EDR Receiver Installation Guide

Page of 184
 
Appendix B 
Module Parameter Descriptions 
144 
78-4025693-01 Rev D 
Hybrid Amplifier Parameters 
Hybrid Amplifier Operating Status Parameters 
 
Parameter 
Name (LCI) 
ICIM 
Abbreviation 
Function 
Typical 
Value 
Optical Input 
Power 
InPwr 
Displays optical input power 
5.0 dBm 
Optical Output 
Power 
OutPwr 
Displays optical output power 
19.5 dBm 
Laser 1 
Temperature 
LasTemp1 
Laser temperature for pump 1 
25°C 
Laser 2 
Temperature 
LasTemp2 
Laser temperature for pump 2 
25°C 
Laser 1 Bias 
Current 
LasBias1 
Laser bias current for pump 1 
0.625 A 
Laser 2 Bias 
Current 
LasBias2 
Laser bias current for pump 2 
3.25 A 
Laser 1 Limit 
LasLim1 
Laser bias current limit for pump 1 
0.825 A 
Laser 2 Limit 
LasLim2 
Laser bias current limit for pump 2 
6.25 A 
Laser TEC 
Current 
TecCur 
Laser TecCooler current for pump 1 
0.25 A 
Module 
Temperature 
ModTemp 
Displays module temperature 
26.5°C 
Laser On Time  LaserOn 
Displays laser ON time 
1.0 Hrs 
Enable Laser 
Enable 
Enables or disables the amplifier 
On 
Optical Power 
Attenuation 
SetAtten 
Attenuates optical output by value 
selected 
0 dB 
Operational 
Mode 
Mode 
Module redundancy control: 
 
If set to Master, unit only controlled 
by Enable controls 
 
If set to Slave, unit only controlled 
by external alarm signal 
Master 
Input Alarm 
Laser Shutdown 
LoInpEna 
Disables low input power alarms and 
shuts down amplifier when optical input 
level falls below -10.0 dBm 
Off 
Service Mode 
Service 
Sets output level to 15 dBm for servicing  Off