Cisco Cisco Prisma II EDR Receiver Installation Guide

Page of 184
 
Appendix B 
Module Parameter Descriptions 
146 
78-4025693-01 Rev D 
Parameter 
Name (LCI) 
ICIM 
Abbrev. 
Nominal 
Value 
Major 
Low 
Limit 
Minor 
Low 
Limit 
Minor 
High 
Limit 
Major 
High 
Limit 
Hys- 
teresis 
Operating 
Range 
Laser 1 
Bias 
Current 
1, 2
 
LasBias1 
3.7 to 
5.0 A 
-8.0 A 
-8.0 A 
-0.1 A 
-0.001 A  0.001 
OK or 
Alarm 
Laser 2 
Bias 
Current 
1, 2
 
LasBias2 
3.7 to 
5.0 A 
-8.0 A 
-8.0 A 
-0.1 A 
-0.010 A  0.001 
OK or 
Alarm 
Laser 
Enable 
Status 
3
 
Enable 
OK or 
Alarm 
Internal 
Power 
Supply 
Status 
4
 
IntPs 
OK or 
Alarm 
Power 
Supply 
Status 
5
 
PsOk 
OK or 
Alarm 
Service 
Mode 
Status 
3
 
Service 
OK or 
Alarm 
1
 Alarm limit values for this parameter are relative to the nominal alarm value. 
2
 Nominal laser bias values are set in manufacturing based on the characteristics of the laser 
diode, and may vary from module to module. Major Low and Minor Low alarm thresholds 
are intentionally set low to avoid false alarms that may be generated at high optical input 
levels (a good condition that corresponds to low bias current). It is recommended that these 
limits not be changed from their factory defaults. 
3
 The alarm values OK and Alarm correspond to the control values OFF and ON, 
respectively. 
4
 This alarm sets the unit to the safe state, in which the optical input is disabled. 
5
 This alarm sets the unit to the safe state, in which the lasers are turned off and optical 
output is disabled.