Cisco Cisco Prisma II EDR Receiver Installation Guide

Page of 47
3-8 
Operation 
78-715189-01 Rev C 
Checking the Operating Settings, 
Continued
 
Checking RF Output 
Complete the following steps to verify that the output level is within ±1.0 dB of the 
value most recently recorded. 
Note: To check the RF output without taking the amplifier out of service, check the 
input test point of the module that the amplifier is feeding. 
1. 
Connect an RF cable from the RF TEST point on the next inline module to the 
spectrum analyzer. 
2. 
Set the spectrum analyzer for the frequency span of your bandwidth. 
3. 
Measure the signal level and tilt and correct for the loss of that module’s RF 
test point. 
4. 
Check that the output level is within ±1.0 dB of the value most recently 
recorded. 
Note: If the reading is not within the proper range, refer to Chapter 4 for 
assistance in troubleshooting. 
5. 
This portion of maintenance is complete. Record the reading. 
6. 
To complete weekly maintenance, go to the next procedure, Checking Pad 
and Tilt Settings
 
Checking Pad and Tilt Settings 
Important: The input and output levels must be verified before any adjustments are 
made to pad and tilt settings. 
Complete the following steps to verify that the settings for pad and tilt are correct. 
1. 
Refer to your Maintenance Log to determine the most recently recorded 
settings for pad and tilt. 
2. 
Compare the recorded settings to the current settings. If either setting does 
not match, use a 1/8-in. flat-blade screwdriver and adjust the setting to the 
value most recently recorded. Or, refer to the appropriate procedure given 
earlier in this chapter. 
• 
Ensuring Proper Signal Strength and Adjusting the Variable Pad 
• 
Ensuring a Flat Output Signal by Adjusting the Variable Equalizer 
3. 
Weekly maintenance is complete. Record the reading.