Operation Using LCI 
4-19 
Check Processor Alarms 
Introduction 
Using LCI, you can check the alarm status of various parameters.  Alarms that you 
can check are listed below. 
 
Alarm  
Alarm Condition 
Indication 
Possible Cause 
Summary Status 
Normal or Alarm 
Alarm 
Any alarm in the 
device. 
Communication 
Status 
Communication fault 
Alarm 
Communication alarm. 
Transmitter 1 
Status 
Transmitter 1 not 
present  
Alarm 
Transmitter 1 not 
present.   
Transmitter 2 
Status 
Transmitter 2 not 
present  
Alarm 
Transmitter 2 not 
present.   
FPGA 1 Status 
FPGA 1 operation 
Alarm 
Indicates the FPGA 1 
failure.  Unit needs 
repair. 
FPGA 2 Status 
FPGA 2 operation 
Alarm 
Indicates the FPGA 2 
failure.  Unit needs 
repair. 
Transmitter 
Communication 
Status 
Communication fault 
Alarm 
Communication alarm. 
Power Supply 
Status 
Power supply 
indicates a fault 
Alarm 
Check power cord.  
Make sure power 
supply is fully seated. 
Clock 1 Status 
Transmitter 1 clock 
operation 
Alarm 
Hardware failure.  Unit 
needs repair. 
Clock 2 Status 
Transmitter 2 clock 
operation 
Alarm 
Hardware failure.  Unit 
needs repair. 
Framing Status 
The signal cannot be 
framed 
Alarm 
Check fiber connection 
path and bdr 
transmitter.