Cisco Cisco Prisma II EDR Receiver Guia Da Instalação
78-748705-01 Rev C
Operation Using LCI
4-19
Check Processor Alarms
Introduction
Using LCI, you can check the alarm status of various parameters. Alarms that you
can check are listed below.
Alarm
Alarm Condition
Indication
Possible Cause
Summary Status
Normal or Alarm
Alarm
Any alarm in the
device.
Communication
Status
Communication fault
Alarm
Communication alarm.
Transmitter 1
Status
Transmitter 1 not
present
Alarm
Transmitter 1 not
present.
Transmitter 2
Status
Transmitter 2 not
present
Alarm
Transmitter 2 not
present.
FPGA 1 Status
FPGA 1 operation
Alarm
Indicates the FPGA 1
failure. Unit needs
repair.
FPGA 2 Status
FPGA 2 operation
Alarm
Indicates the FPGA 2
failure. Unit needs
repair.
Transmitter
Communication
Status
Communication fault
Alarm
Communication alarm.
Power Supply
Status
Power supply
indicates a fault
Alarm
Check power cord.
Make sure power
supply is fully seated.
Clock 1 Status
Transmitter 1 clock
operation
Alarm
Hardware failure. Unit
needs repair.
Clock 2 Status
Transmitter 2 clock
operation
Alarm
Hardware failure. Unit
needs repair.
Framing Status
The signal cannot be
framed
Alarm
Check fiber connection
path and bdr
transmitter.