Cisco Cisco Prisma II EDR Receiver Installation Guide

Page of 139
2-22 
Installation 
78-748705-01 Rev C 
Interface Panel Installation and Connections 
Introduction 
The following instructions explain how to: 
• 
Connect the Prisma II Redundancy Interface Panel to a chassis 
• 
Connect a slave module to a master module 
• 
Check the master/slave connection 
Cabling Requirements 
The table below shows the items required to install the interface panel and to 
connect a slave module to a master module. 
 
Item 
Function 
Two DB-37 cables 
Serve as extensions of the ALARMS IN and 
ALARMS OUT connectors on the chassis 
Jumper wire, 20-gauge insulated  Makes hard-wire connections between spring 
terminals.  It is to be cut to length, end-stripped, 
and inserted in the spring terminal. 
Wire routing clips 
Gather loose jumper wires near the interface 
panel 
Mounting screws (not included)  Mount the interface panel in a rack 
Screwdriver (not included) 
Tightens the mounting screws in the interface 
panel 
Ground cable (not included) 
Ties the interface panel to earth ground