Cisco Cisco Prisma II EDR Receiver Installation Guide

Page of 139
2-24 
Installation 
78-748705-01 Rev C 
Interface Panel Installation and Connections,
 Continued 
Connecting a Slave Module to a Master Module 
Follow these steps to connect a slave module to a master module using the interface 
panel. 
Notes:   
• 
To configure a module as master or slave, use the ICIM, the LCI software, or TNCS 
software as shown in the guide that was shipped with the specific Prisma II 
module. 
• 
For information about typical master/slave connections, refer to Master/Slave 
Connections Overview later in this chapter. 
 
1. 
On the ALARM OUT strip at the front of the interface panel, locate the slot 
number representing the chassis slot location of the master module.  Connect 
one end of a jumper wire to spring terminal A of that slot number. 
2. 
Connect the other end of the same jumper wire to the A terminal of the slot of 
the slave module on the ALARMS IN connector.  This connection may or 
may not be on the same interface panel. 
3. 
Repeat steps 1 and 2 for the B terminals of both the master and the slave 
module’s ALARM IN and ALARM OUT terminal strips. 
4. 
Upon connecting all wires, adhere the wire routing clips to the interface panel 
and connect the wires onto the clips. 
Checking the Master/Slave Connection 
Follow these steps to verify that the master/slave connection is operating properly. 
 
1. 
Ensure that all master and slave modules are installed, power is applied to 
your system, and all cable connections between the chassis and the interface 
panel(s) are secure. 
2. 
Verify that the primary module is configured to operate as a master and the 
backup module is configured to operate as a slave (or as externally redundant 
when connecting bdr processors). 
3. 
Ensure that all jumper wires are securely connected to the proper terminals. 
4. 
When the system is powered and properly configured, remove the master 
module and verify that the slave module turns on and begins operation.  If 
the slave does not operate, review the installation and connection steps given 
in this section.