Cisco Cisco Customer Response Solution Downloads Troubleshooting Guide

Page of 154
 
8-37
Cisco Unified Contact Center Express Servicing and Troubleshooting Guide, Release 7.0(1)
 
Chapter 8      Troubleshooting Tips
Cisco Unified CCX Engine Problems
Application subsystem is in partial service
Symptom   
The Engine Status area in the Engine web page shows that the Application subsystem is in 
partial service.
Error Message   
None.
Possible Cause   
Some applications are invalid. 
Recommended Action   
Perform these actions:
Step 1
Refer to the Cisco Unified CCX trace files to identify the invalid application.
Step 2
Validate the corresponding script using the Cisco Unified CCX Editor.
Cisco Unified CCX Engine is running but calls are not answered
Symptom   
The Cisco Unified CCX Engine is running but the Cisco Unified CCX system does not answer 
calls.
Error Message   
None
.
Possible Cause   
The JTAPI subsystem is out of service, the trigger is disabled, the application is disabled, 
the maximum number of sessions or maximum number of tasks were exceeded, or no CTI ports or media 
channels are available for the trigger.
Recommended Action   
Complete the following steps:
Step 1
From the Cisco Unified CCX Administration web page, choose System > Control Center, pick up the 
servers on the left panel, and expand the Cisco Unified CCX Engine to verify that the JTAPI subsystem 
is in service. 
If the JTAPI subsystem is in partial service, see the “JTAPI subsystem is in partial service” 
troubleshooting tip in this guide. 
If the JTAPI subsystem out of service, refer to the “Cisco Unified CCX Provisioning for Cisco Unified 
Communications Manager” section in the Cisco Unified Contact Center Express Administration Guide 
for information about configuration.
Step 2
From the Cisco Unified CCX Administration web page, choose Subsystems > JTAPI and click the 
JTAPI Triggers hyperlink. If False appears in the Enabled column for the trigger, double-click the 
trigger, click the Enabled Yes radio button, and then click Update.
Step 3
From the Cisco Unified CCX Administration web page, choose Applications > Configure 
Applications
. If No appears in the Enabled column for the application, double-click the application, 
click the Enabled Yes radio button, and then click Update.
Step 4
In the Cisco Unified CCX trace files, verify that the calls do not exceed the maximum number of allowed 
sessions.
Step 5
In the Cisco Unified CCX trace files, verify that the calls do not exceed the maximum number of allowed 
tasks.