Cisco Prisma MediaCenter 2 & 8 Slot Chassis Installation Guide

Page of 26
4008357 Rev B 
Prisma DS3/E3/STS-1 Media Converter Module Installation Instructions 
Configuration Instructions 
Introduction 
The Prisma DS3/E3/STS-1 module can be configured for various features (see DIP 
Switch Settings 
later in this document) that help improve the performance and 
reliability for your requirements.  The following instructions are for both managed 
and unmanaged modules. 
Managed Modules 
To manage Prisma DS3/E3/STS-1 modules, an SNMP agent must be present i.e., the 
MediaCenter chassis with embedded management; MediaCPE chassis require an 
SNMP-management module.  When using Prisma DS3/E3/STS-1 modules in a 
managed environment, manually configure the features that you cannot configure 
via management software prior to installation of the module.  (See Choosing Your 
Settings
 and DIP Switch Settings later in this document for configuration 
instructions/description of the functions).  After completing necessary pre-
installation settings, install the Prisma DS3/E3/STS-1 module (see Module 
Installation Instructions
 later in this document), and configure additional features 
via the software. 
The features that are configurable via management software include: Loopback 
Selection, FiberAlert, Transmit Data Source, Jitter Attenuation, and Line Buildout.  
Within the PrismaView
 software for media conversion, these settings are 
configured in the Module Detail section of the main viewing screen, under the 
picture of the module.  Refer to the help file for more information. 
Note:  Management software overrides any hardware settings (e.g., jumper, switch, 
etc.), so you MUST configure a module that will be managed via the software.  Until 
a module installed in a managed chassis is configured via the software, the module 
(and its LEDs) may not work properly. 
Important:  When testing, it is recommended that you test your modules first in an 
unmanaged environment.  To do this, turn the SNMP management switch to OFF on 
a MediaCenter chassis, or remove the management module from a MediaCenter 
chassis.  Follow the unmanaged configuration instructions, then install the module, 
connect the cables, and test the LEDs.  When finished, reactivate management and 
configure the unit via the software. 
 
Continued on next page