Troubleshoot Alarm Conditions 
Introduction
 
If the red ALARM indicator is illuminated or blinking, check the ICIM to determine 
the cause of the alarm.  Blinking = minor alarm, steady illumination = major alarm. 
ICIM Alarm Conditions 
The table below shows the alarm conditions and possible causes. 
 
Alarm  
Alarm Condition 
Indication 
Possible Cause 
DCPower 
Power supply indicates 
a fault 
Fault 
Check power cord.  Make sure 
power supply is fully seated. 
ProcTemp 
Module Temperature 
Fault 
Check fan tray operation. 
RdnInvld 
Redundant mode 
invalid 
Invalid 
Both receivers are configured 
to Internal redundancy with 
no master. 
Rcv1Inst 
Receiver 1 not present  
Fault 
Receiver 1 not present.  
Rcv1Bias 
(APD Rx only) 
APD 1 bias incorrect 
Fault 
Re-seat receiver 1.  Replace if 
necessary. 
Rcv1_LOS 
Receiver 1 loss of signal 
Fault 
Check fiber line and data into 
receiver 1. 
Rcv1Data 
Receiver 1 no data 
Fault 
Check fiber line into receiver. 
Rcv2Inst 
Receiver 1 not present  
Fault 
Receiver 2 not present.  
Rcv2Bias (APD 
Rx only) 
APD 2 bias incorrect 
Fault 
Re-seat receiver 2. Replace if 
necessary. 
Rcv2_LOS 
Receiver 2 loss of signal 
Fault 
Check fiber line and data into 
receiver 2. 
Rcv2Data 
Receiver 2 no data 
Fault 
Check fiber line into receiver.