Introduction 
1-11 
Processor Configuration Options,
 Continued 
Alarms 
While this module contains no user-configurable alarm thresholds, some alarms may 
occur because of user-configurable settings or user action.  The following are several 
examples of when an alarm can occur. 
• 
All outputs are muted 
• 
An optical receiver is removed when in redundant mode 
• 
Optical input cables are disconnected 
Alarm conditions for specific parameters are labeled as Major, Minor, or Fault.  
Major and minor alarms designate if the parameter in alarm is of too high a value 
(MajorH) or too low a value (MajorL). 
Major alarms produce a constant, illuminated red LED on the processor front panel, 
while minor alarms produce a blinking red LED.  Alarm conditions can be 
investigated using the ICIM, LCI software, or TNCS software.   
For additional information, refer to: 
• 
Check Processor Alarms Using the ICIM in Chapter 3 
• 
Check Processor Alarms in Chapter 4 
• 
Chapter 3, Operation Using the ICIM  
• 
Chapter 4, Operation Using LCI 
Test Point Selector and -20 dB Test Point  
The processor front panel houses a test point selector and a -20 dB test point.  The 
test point selector configures which RF input (1A, 2A, 1B, or 2B) the –20 dB test point 
represents.  The test point provides a –20 dB sample of the selected RF input signal.