Cisco Cisco Prisma II EDR Receiver Installation Guide

Page of 137
1-12 
Introduction 
78-748704-01 Rev C 
Processor Configuration Options,
 Continued 
Redundant Mode 
Both optical receivers installed in the processor may be configured to operate as 
either a MasterInternal, or External optical receiver as explained below and 
illustrated on the following pages. 
 
Receiver 
Type 
Description 
Master 
The primary optical receiver.  You can configure one, both, or neither 
of the optical receivers in the same processor as Master
• 
If both optical receivers in the same processor are configured as 
Master, they have no internal backup and can only be backed-up 
by an identical optical receiver configured as External. 
• 
If only one is configured as Master, the other optical receiver in 
that processor may also operate in one of the two redundant 
modes listed below. 
• 
If neither optical receiver in a processor is configured as Master, 
they must operate in one of the two redundant modes listed below. 
Master is the default setting. 
Internal 
Internally redundant to an optical receiver located in the same 
processor. 
• 
With one optical receiver configured to Master, the other optical 
receiver in the same processor can be configured as Internal 
(internally redundant), providing backup to the master optical 
receiver. 
• 
When configured to Internal, an optical receiver’s output is 
activated only if the master optical receiver in the same processor 
fails.  Two optical receivers in the same processor cannot be 
configured to Internal, as they would both be internal redundant 
with no master to back-up.  Two optical receivers in the same 
processor configured to Internal will generate an RdnInvld alarm 
on the ICIM and an Invalid Redundant Receiver alarm when 
using LCI or TNCS software. 
External  Externally redundant to an optical receiver located outside of the 
processor.  You can configure one, or both, or neither of the optical 
receivers in the same processor as External.  When configured to 
External, an optical receiver is redundant to an optical receiver located 
in a separate processor.  When configured as External, the optical 
receiver’s output is activated only if the master optical receiver located 
in the other processor fails.