Cisco Cisco TelePresence MX700 Release Note
Known limitations
Cisco TelePresence System C-Series Software Release Notes
Page 68 of 133
* Log into the TMS Web Interface, browse to
the system and do a ‘Force Refresh’. TMS
should communicate to the system properly and
the error message will clear.
* To minimize service abruption it will be
* To minimize service abruption it will be
beneficial to upgrade all systems in one go,
avoiding following the above procedure for
every endpoints you upgrade. A future TMS
version will resolve this condition negating the
need to restart the services.
Workaround to restore the releasekeys:
* Once TMS has restored communication with
Workaround to restore the releasekeys:
* Once TMS has restored communication with
the systems, upgrade the units one more time.
This time TMS will be able to communicate with
the systems when they boot up and set the
releasekeys.
Note: Please read the resolved caveats
Note: Please read the resolved caveats
section Reference ID 85930 as well.
Note: The above issues are fixed for TMS
Note: The above issues are fixed for TMS
13.0
76765
Any
Dialing from an unregistered endpoint to a
registered endpoint using the format:
remotesystem@company.com will not work
62204
TANDBERG PrecisionHD 1080p Camera
all SW versions.
720p50, 720p30 and 720p25 output has no
CRC included for HD-SDI. Depending on the
device you connect the camera to, you may not
get video using this format. The TANDBERG
codec will support these formats.
Ver. TC2.1.0 and above
Startup scripts will not work with Windows end
of line. You must use Unix end of line to be able
to run multiple commands. Most editors have
the option to set which format to use. If you use
Notepad ++, you can set Unix format in the
Settings/Preferences menu.
Settings/Preferences menu.
67092
Ver. TC2.1.0 and above.
Composite and S-Video video input is shaking.
However some improvements have been made
within TC2.0.
Ver. Any
If you run cascaded cameras and the chained
cameras are running an old camera code, we
have seen that only zoom works when trying to
control the chained camera. The solution is to
control the chained camera. The solution is to
connect the cascaded camera as the first
camera in the chain so that the camera is
detected and upgraded by the codec, or use the
Ethernet upgrade method.
Ver. Any
HD-SDI may not work with cables shorter than
3 meters. This is due to a jitter issue.
3 meters. This is due to a jitter issue.
Ver.Any
If you turn off H.323 as the protocol but leave
default protocol as H.323 you will be unable to
make outgoing calls unless you edit the URI to
include 'sip:' in front of the number or change