ACR Electronics ffmc User Manual

Page of 26
Y1-03-0199 Rev. C 
 
16 
SECTION 6 - CARE AND MAINTENANCE  
 
At least every ninety days, the mounting bracket and float free memory capsule should be inspected for deterioration 
and/or buildup that may affect the function of the memory capsule or automatic release. 
 
Also carefully inspect the memory capsule case for any visible cracks. Cracks may admit moisture, which could falsely 
activate the memory capsule or otherwise cause a malfunction. Any cracking observed should be immediately returned 
for repairs (See returning product information on page 1). 
 
Clean the memory capsule and the mounting bracket to remove residue buildups. It is recommended that the mounting 
bracket be wiped with a damp cloth. 
 
The  hydrostatic  release  unit  (HRU)  must  be  replaced  by  the  date  indicated  on  the  float  free  mounting  bracket.  The 
hydrostatic  release  can  be  replaced  by  removing  the  memory  capsule  from  the  bracket,  then  sliding  the  hydrostatic 
release  assembly  out  of  the  keyed  opening  on  the  spring  and  mounting  bracket.  Insert  the  new  hydrostatic  release 
assembly,  in  place  by  engaging  it  to  the  opening  of  the  ejection  spring  and  case.  When  servicing  the  HRU,  it  is 
required that you replace the entire hydrostatic assembly,  including hydrostatic release, release rod and all hardware 
(P/N  9490  Universal  kit).  Failure  to  replace  the  entire  assembly  can  cause  the  bracket  to  malfunction.  Always  use 
original  ACR  replacement  parts.  Use  of  unauthorized  replacement  parts  will  void  your  warranty  and  may  cause  the 
bracket  to  malfunction.  Place  memory  capsule  into  the  mounting  bracket,  and  replace  cover,  securing  in  place  with 
hitch pin going through the hydrostatic release rod. 
 
Check antenna for tightness. 
 
The battery (P/N 1078) must be replaced by the date indicated on the memory capsule. At each inspection, check the 
time remaining until replacement is required. Battery should be replaced if the memory capsule has been activated for 
any use other than the self test. 
 
NOTE:  There  are  no  user  serviceable  items  inside  the  memory  capsule.  DO  NOT  OPEN  THE  MEMORY 
CAPSULE EXCEPT TO DISABLE IN CASE OF FAULTY ACTIVATION.  
 
Self  contained  long  life  batteries  with  a  five-year  recommended  replacement  cycle  provide  power.  See  factory 
authorized service center for replacement. 
 
 
Battery replacement includes servicing the memory capsule by replacing the lithium batteries, o-rings, testing the water 
seal and the electrical properties.  
 
Always refer all long life battery replacement and other memory capsule service to a factory authorized service center. 
For battery replacement information, please refer to Section 10. 
The  memory  capsule  contains  lithium  batteries  which  meet  the  requirements  of  the  DOT  Hazardous  Materials 
Regulations. They also meet the United Nations Classification of Lithium Batteries for Shipment as "Non 
– Dangerous 
Goods". 
 
Data transfer cable cutting mechanism 
 
Like the HRU, the data transfer cable and cutting mechanism (ACR P/N 2518) should be replaced every two years.