Alcatel-Lucent omniacces-voip gateway User Manual
VoIP Commands
Page 5-137
Command Usage
Specify Foreign Exchange Office Ground Start (FXS GS) debounce interval for loop open
detection.
detection.
Syntax Options
Remarks
The
voice signaling protocol
command must be set to the corresponding protocol type before
any commands for E&M (Wink Start, Immediate Start, and Delay Start Signaling), and FXS/
FXO (Loop and Ground Start) commands will take effect.
FXO (Loop and Ground Start) commands will take effect.
voice signaling fxo gs connection loop open debounce
voice signaling channel <
slot/port/startChannel-endChannel
> fxo gs connection loop open
debounce <
value
>
Definitions:
slot
slot
Specifies chassis slot number where VSM is installed, (e.g.,
2
).
port
Specifies physical port number on voice daughtercard, (e.g.,
1
).
startChannel
The first number in the range of voice channels (e.g.,
1
).
endChannel
The last number in the range of voice channels (e.g.,
30
).
♦ Syntax Note ♦
Be sure to separate the start and end range numbers with a
hyphen (e.g.,
1-30
).
value
Specifies the debounce (delay interval) for loop open detection for existing connection, in
milliseconds from 1 to 60,000, (e.g.,
milliseconds from 1 to 60,000, (e.g.,
150
).
♦ Syntax Note ♦
Do not use commas when entering the fxs gs debounce interval
value for loop open detection (for example,
value for loop open detection (for example,
1,000
will return a
syntax error message).
Default:
The default value is
The default value is
150
milliseconds.
Command Examples:
voice signaling channel 2/1/1-12 fxo gs connection loop open debounce 150
voice signaling channel 2/2/13-24 fxo gs connection loop open debounce 30000
voice signaling channel 2/3/1-30 fxo gs connection loop open debounce 60000
voice signaling channel 2/2/13-24 fxo gs connection loop open debounce 30000