Alcatel-Lucent omniacces-voip gateway User Manual

Page of 430
VoIP Commands
Page 5-190
Command Usage
Set coding profile voice activity threshold mode (adaptive/relative).
Syntax Options
Remarks
This command is used to set the audio threshold level (in dBm) for the voice activity detec-
tor (VAD) for a coding profile to be adaptive or relative to a reference level of -30 dBm.
voice coding profile voice activity detection threshold mode
voice coding profile <
“codingProfName”
 > voice activity detection threshold mode 
{adaptive | relative}
Definitions:
codingProfName
Identifies coding profile by name, (e.g., 
salemprof1
); maximum length of 40 characters. 
The following characters are permitted in the coding profile name: a-z, A-Z, 0-9, space and 
# * ~ ’ ‘ ; : , .@ $ % ^ _ & | / \ < > ( ) [ ] { }
adaptive
Indicates adaptive voice activity detection audio threshold mode for specified coding pro-
file.
relative
Indicates relative voice activity detection audio threshold mode for specified coding pro-
file.
 Syntax Notes 
To use this command, the voice activity detector mode must be 
enabled via the 
voice coding profile voice activity detector 
command.
If this command is adaptive in the switch, the threshold value is 
automatically 32767 dBm.
If this command is relative in the switch, the voice activity detec-
tion has no bearing on the hardware or VoIP.
Default:
The default setting is 
adaptive
.
Command Example:
voice coding profile salemprof1 voice activity detection threshold mode adaptive