dedicated workstation for managing and configuring the access point and the 
wireless network.
P
OWER
 R
EQUIREMENTS
The access point complies with the IEEE 802.3af power-over-Ethernet standard. It 
receives power over standard category 5 straight (8-wire) Ethernet cable. Installation 
requires the use of either the 3Com power supply provided or IEEE 802.3af compliant 
power supply equipment (output power rated 48 V dc @ 350 mA maximum). Such 
equipment must be safety certified according to UL, CSA, IEC or other applicable 
national or international safety requirements for the country of use. All references to 
the power supply in this document refer to equipment that meets these requirements. 
Because the power supply plug is the only means of disconnecting the access point 
from power, make sure the power outlet is accessible.
S
AFETY
 I
NFORMATION
This equipment must be installed in compliance with local and national building codes, 
regulatory restrictions, and FCC rules. For the safety of people and equipment, only 
professional network personnel should install the access point, cables, and antennas. 
Note for use of the 3Com power supply (part number 61-0107-000) in Norway: This 
product is also designed for use on an IT power system with phase-to-phase voltage of 
230 V.
CAUTION: If you supply your own Ethernet cable for connecting power, be sure that it is 
category 5 straight-through (8-wire) cable that has not been altered in any way. Use of 
nonstandard cable could damage the access point.
CAUTION: To comply with FCC radio frequency (RF) exposure limits, a minimum 
body-to-antenna distance of 1 meter (3 feet) must be maintained when the access point 
is operational.
CAUTION: To avoid possible injury or damage to equipment, you must use either the 
provided power supply or IEEE 802.3af compliant power supply equipment that is safety 
certified according to UL, CSA, IEC, or other applicable national or international safety 
requirements for the country of use. All references to power supply in this document refer to 
equipment meeting these requirements.
CAUTION: The 3Com power supply (part number 61-0107-000) input relies on a 16A rated 
building fuse or circuit protector for short circuit protection of the line to neutral conductors.