Installing the Switch
Included Parts
Installation Precautions
  W A R N I N G
The rack or cabinet should be adequately secured to prevent it 
from becoming unstable and/or falling over.
Devices installed in a rack or cabinet should be mounted as low as 
possible, with the heaviest devices at the bottom and progressively 
lighter devices installed above.
Wall-mount the Switch 2520G-8-PoE with network ports facing up 
(away from the floor). Do not wall-mount the switch with the 
network ports facing down (toward the floor) or ventilation ducts 
facing up or down.
  C a u t i o n s
Use only the AC/DC power adapter supplied with the Switch 2520G-8-PoE 
for connection to an AC power source.
Ensure the power source circuits are properly grounded, then use the 
power cord supplied with the switch to connect it to the power source.
If your installation requires a different power cord than the one supplied 
with the switch, ensure the cord is adequately sized for the switch’s 
current requirements. In addition, be sure to use a power cord displaying 
the mark of the safety agency that defines the regulations for power cords 
in your country. The mark is your assurance that the power cord can be 
used safely with the switch. If the supplied power cord does not fit, 
contact ProCurve Networking support.
When installing the switch, the AC outlet should be near the switch and 
should be easily accessible in case the switch must be powered off.
Ensure the switch does not overload the power circuits, wiring, and over-
current protection. To determine the possibility of overloading the supply 
circuits, add together the ampere ratings of all devices installed on the 
same circuit as the switch and compare the total with the rating limit for 
the circuit. Maximum ampere ratings are usually printed on the devices 
near the AC power connectors.
Do not install the switch in an environment where the operating ambient 
temperature might exceed 50
°C (122°F). This includes a fully-enclosed 
rack. Ensure the air flow around the sides and back of the switch is not 
restricted. Leave at least 7.6 cm (3 inches) for cooling. 
Ensure all port covers are installed when the port is not in use.