Nikon COOLPIX 4500 Maintenance Manual

Page of 65
VAA11901-R.3579.A
- A4・E4500 -
Put it between the eye-
piece unit and the termi-
nal
• Attach the support plate.
• Set the upper lens mold unit and attach the
  screw
(1.7 x 3.5), the screw
(1.7 x 5) and
  the screw
(1.7 x 3.5).
• Pull out the wire from the connector
from
  the bottom and connect it.
 The wires should not be seen when you 
look at the unit from the side pointed by an 
arrow in Figure 1.
• Apply a piece of tape (black) and a piece of 
  tape (white). [Refer to Figure 1.]
• Set the eyepiece unit to the lens side lower
  cover, and then attach the lens side lower
  cover.
• Attach the screw
(1.7 x 3.5) and 2 screws
  
(1.7 x 3.5).
• Arrange the wires from the terminal unit and
  then connect the connector
⑦ .
• Attach the lens side upper cover with the 2
  screws
(1.7 x 3.5) and the 2 screws
(1.7
  x 3.5).
• Attach the name plate.
Name plate
Lens side upper cover
Connector ⑦
Lens side lower cover
Support plate
Connector ④
Upper lens 
mold unit 
Tape (Black)
Tape (White)
[Arrangement of wires from the terminal unit]
Fig. 1
Eye 
piece
5. Lens cover