Sony DXC-990 User Manual

Page of 180
DXC-990/990P
3-205-543-11 (1)
D:\Nouhin\DXC990UC\320554311DXC990UC\02GB-
DXC990UC\04ADJ.fm
masterpage:Left
GB 
12
EXPOSURE Menu
Selects the electronic shutter modes.
OFF
Any electronic shutter mode does not 
function.
STEP
Select to set the shutter speed to any of 4 
steps in long-exposure mode and 11 steps in 
high-speed mode.
SPEED
Sets the shutter speed.
To set the shutter speed
1
Select SPEED by pressing the 
V or v 
button.
2
Display OFF by pressing the 
B and b 
buttons simultaneously.
3
Press the 
B button to set the speed for 
long-exposure mode, or press the 
b button 
to set it for high-speed mode.
4
Each press changes the shutter speed.
VARIABLE
Use for fine adjustment of the video output 
level in units of 1 frame (long exposure 
mode) or in units of 1H (horizontal scanning 
time: 63.56 
µ
s for DXC-990, 64.00 
µ
s for 
DXC-990P) (clear scan mode).
In long exposure mode, for example, if you 
set to 10 frames (about 0.33 seconds), the 
video signal produced during this set time is 
output in the form of one complete frame at 
intervals of about 0.33 seconds. These 
pictures, which contain 10 frames of video 
information, are much brighter than normal 
one-frame images. This mode is useful for 
shooting a poorly illuminated object in a 
dark place.
The clear scan mode can be used for 
shooting computer displays with reduced 
horizontal bands appearing across the 
display screen. Adjust the value while 
observing the noise on the monitor screen so 
that you can obtain the image with minimum 
noise.
SPEED 
Sets the shutter speed.
To set the shutter speed
1
Select SPEED by pressing the 
V or v 
button.
2
Display OFF by pressing the 
B and b 
buttons simultaneously.
3
Press the 
B button to set the speed for 
long-exposure mode, or press the 
b button 
to set it for clear scan mode.
4
Each press changes the shutter speed.
To convert the value into the shutter 
speed
Long-exposure mode
Example: When the value is set to 5 frames
×
 1/30 = 0.1666 seconds (DXC-990)
×
 1/25 = 0.2000 seconds (DXC-990P)
Clear scan mode
Example: When the value is set to 250H
DXC-990:
250 
×
 63.56 
µ
s (1H) + 34.9 
µ
s (constant) 
= 15924.9 
µ
s = Approx. 0.016 seconds
DXC-990P:
250 
×
 64.00 
µ
s (1H) + 35.0 
µ
s (constant) 
= 16035.0 
µ
s = Approx. 0.016 seconds.
Do not use AGC, CCD-IRIS, ATW, AWB 
DCC+ and DYNALATITUDE functions in 
long exposure mode.
Set the gain level to 0 dB.
CCD-IRIS
Automatically adjusts the luminance level 
for optimum output level. When incoming 
light is excessive, this function 
automatically adjusts the shutter speed to cut 
exposure equivalent to up to 10 aperture 
stops.
LIMIT
Sets the maximum shutter speed to be 
adjusted to 1/250, 1/500, 1/1000, 1/2000, 
1/4000, 1/10000, 1/20000,1/40000 or 
1/100000.
Selects the iris mode.
SHUTTER
Note
IRIS