Sony HD 3CCD User Manual

Page of 80
Ov
er
v
ie
w
Location and Function of Parts
19
EXT SYNC IN connector
Accepts external video sync signals.
Card slot
Insert an optional interface board, HFBK-HD1, 
HFBK-SD1, HFBK-XG1, HFBK-TS1 or BRBK-
H700.
The slot cover is attached to the camera at the 
factory.
Q
 RGB/COMPONENT connector
Supplies the images as analog component (YPbPr 
or RGB) signal.
DATA MIX switch
Set the switch to ON to overlap the menu with the 
video signal output from the installed interface 
board. Set it to OFF not to overlap the menu.
Cable cover
The cable cover is attached to the camera at the 
factory. To remove the cable cover, see page 50.
Note
Do not carry the camera by holding the cable cover. 
Otherwise, the cable cover may come off and the 
camera may fall.
Bottom
Ceiling bracket mounting screw holes
When you install the camera to the ceiling, secure 
the supplied ceiling bracket to these holes using the 
supplied four screws. The four feet are attached to 
the holes at the factory.
Tripod screw holes (1/4-20UNC)
When you install the camera to a tripod, secure the 
tripod to these holes.
BOTTOM switches
Used for the output signal format selection, RS-
232C/RS-422 selection, baud rate selection, remote 
control signal output on/off and camera address 
setting.
Setting of the BOTTOM switches
1
Switch 1 (59.94i/50i signal format selector)
Set to ON for output of 50i signal format, or OFF 
for output of 59.94i signal format.
2
Switch 2 (RS-232C/RS-422 selector)
Set to ON for RS-422, or OFF for RS-232C.
3
Switch 3 (Communication baud rate selector)
Set to ON for 38400bps, or OFF for 9600bps.
4
Switch 4 (Infrared signal output switch)
Set to ON to enable an infrared signal output, or 
OFF to disable the output.
5
Camera address selectors
Set the address of the camera.
Normally set to “0”.  With this setting, addresses 
are assigned to the cameras automatically in the 
connected order by pressing the POWER button 
while holding down the RESET button on the RM-
BR300 Remote Control Unit.
You can assign the camera address “1” to “7” 
manually by setting these selectors as follows:
Switch 4 is not used.
Note
Set the switches before you turn on the power of the 
camera.
wa
w;
ws
Camera 
address
0
1
2
3
4
5
6
7
Switch 1
OFF ON
OFF ON
OFF ON
OFF ON
Switch 2
OFF OFF ON
ON
OFF OFF ON
ON
Switch 3
OFF OFF OFF OFF ON
ON
ON
ON
O
N
1
2
3
4
O
N
1
2
3
4
2
1
4
5
3