Sony HD 3CCD User Manual

Page of 80
A
ppe
ndix
Troubleshooting
65
 
Troubleshooting
Before bringing in your camera for service, check the 
following as a guide to troubleshoot the problem. If the 
problem cannot be corrected, consult with your Sony 
dealer.
Symptom
Cause
Remedy
The power of the camera is not turned 
on.
The AC power adaptor is not connected to the 
DC IN 12V jack firmly.
Insert the power cord firmly as far as it will 
go.
The AC power cord is not inserted firmly into 
the AC power adaptor or the AC outlet.
Insert the power cord firmly as far as it will 
go.
The BRBK-H700 HD Optical Multiplex Card 
is inserted into the card slot.
Remove the card from the card slot.
When using the far distance remote control 
system with the BRBK-H700 Optical 
Multiplex Card, CCFC-M100HG Optical 
Fiber Cable and BRU-H700 HD Optical 
Multiplex Unit, the Optical Fiber Cable is not 
properly connected or the HD Optical 
Multiplex Unit is not turned on.
Insert the Optical Fiber Cable firmly as far as 
it will go.
Turn on the HD Optical Multiplex Unit, or 
plug in the power cord of the unit to an AC 
outlet firmly.
The camera cannot be turned on with the 
supplied Remote Commander.
IR-RECEIVE in the SYSTEM menu is set to 
OFF.
Use the RM-BR300 Remote Control Unit to 
open the menu and set IR-RECEIVE to ON. 
(page 35)
The picture is not displayed on the video 
monitor connected to the camera.
The video cable is not connected properly.
Check the connection between the camera and 
video monitor.
The exposure is not set correctly on the 
camera.
Set the exposure correctly in the EXPOSURE 
menu.
Pan, tilt or zoom cannot be operated.
Any menu is displayed on the monitor screen. Press the DATA SCREEN button on the 
supplied Remote Commander or the MENU 
button on the RM-BR300 Remote Control 
Unit to turn off the menu from the monitor 
screen.
The panning or tilting range is limited.
Change the PAN-TILT LIMIT setting in the 
PAN TILT ZOOM menu (page 34).
The Remote Commander does not work. The CAMERA SELECT button you pressed 
on the Remote Commander does not match 
the number set with the IR SELECT switch 
on the camera.
Press the CAMERA SELECT button 
corresponding to the IR SELECT switch 
setting on the camera (page 40).
The camera cannot be operated with the 
RM-BR300 Remote Control Unit.
The connection using the VISCA RS-422 
connectors is not correctly made.
Check that the connection to the VISCA RS-
422 connectors is correctly made, and the RS-
422 cable is properly connected.
The BOTTOM switch on the bottom of the 
camera is set to any other address than “0 
(AUTO).”
Identify the address of the camera (page 19), 
then set the MODE selector on the rear of the 
Remote Control Unit to the same address 
(page 23).
VISCA control setting is not correct.
Select the proper setting (RS-232C or RS-
422) with the BOTTOM switch on the bottom 
of the camera (page 19) and the DIP switch on 
the Remote Control Unit (page 23).
The communication baud rate setting of the 
camera and the RM-BR300 differ.
Select the same communication baud rate 
(9600 bps or 38,400 bps) with the BOTTOM 
switch on the bottom of the camera (page 19) 
and the DIP switch on the Remote Control 
Unit (page 23).
The NC (No Connection) switch is set to ON. Set camera address selector switch 4 of the 
BOTTOM switches on the bottom of the 
camera to OFF (page 19).