Sony SNC-RZ30N User Manual

Page of 44
Ad
minis
tra
ting t
he Camer
a
Setting the Alarm Out 1 or 2 — Alarm out 1 or 2 setting Page
34
Setting the Alarm Out 1 
or 2 
— Alarm out 1 or 2 setting Page
When you click Alarm out 1 on the Administrator 
menu, the Alarm out 1 setting page appears.  When you 
click Alarm out 2 on the Administrator menu, the 
Alarm out 2 setting page appears.
Use these pages to set up for the Alarm out function that 
controls the alarm out 1 or alarm out 2 of the I/O port 
located on the rear the camera.  You can control the 
alarm out when a trigger occurs by an external sensor 
input, the built-in activity detection function, a manual 
trigger button, the Day/Night function or the timer.
The setting items for alarm out 1 and alarm out 2 are the 
same.  This section explains how to set alarm out 1 as an 
example.
Activating/Deactivating the Alarm 
Out 1 Function 
— Alarm out 1 usage setting Page
To activate the Alarm out 1 function, select Use alarm 
out 1 function
 and click OK.  The Alarm out 1 setting 
page appears.
When you do not use the Alarm out 1 function, select Do 
not use alarm out 1 function
 and click OK.
Setting the Alarm Out 1 Function 
— Alarm out 1 setting Page
Mode
Select the mode of the Alarm out 1 function.
Manual: Controls the alarm out 1 manually. 
In this mode, you can short-circuit and open the 
alarm out 1 by clicking the 
 (Trigger) button on 
Day/Night: Controls alarm out 1 by synchronizing with 
the Day/Night function of the camera.  When you 
select Day/Night, the Day/Night setting button 
appears.  Click the button, and the Camera setting 
page appears and you can set the Day/Night function 
(see page 21).
In the Night mode, the relay corresponding to the 
alarm out 1 is short-circuited.  In the Day mode, it is 
open.
Alarm: Controls alarm out 1 by synchronizing with an 
external sensor input or the built-in activity detection 
function.  When you select Alarm, the Alarm mode 
setting section appears (see page 34).
Timer: Controls alarm out 1 by the timer.  When you 
select Timer, the Timer mode setting section appears 
(see page 35).
Alarm mode setting Section
Alarm
Select the alarm to link the alarm out 1 function.  If the 
selected alarm is detected, the alarm out 1 status 
changes.
Sensor 1: External sensor connected to sensor input 1 of 
the camera I/O port 
Sensor 2: External sensor connected to sensor input 2 of 
the camera I/O port 
Sensor 3: External sensor connected to sensor input 3 of 
the camera I/O port 
Activity detection: The activity detection function built 
in the camera. 
To set the activity detection function, click Activity 
detection
.  The Activity detection setting page 
appears (see page 40).
Available period
Select the period for which the alarm mode is available.
Always: The alarm mode is available any time.
Use scheduler: The alarm mode is available according 
to the schedule selected on the Schedule No. menu 
below.
Schedule No.
When Use scheduler is selected on the Available period 
menu, select the schedule you want the alarm mode 
being available.
Click to select the check box(es) 1 to 6.  You can select 