Sony VPL-FX40 User Manual

Page of 58
45
Troubleshooting
Oth
e
rs
Remote Commander
Others
Indicators
Symptom
Cause and Remedy
The Remote Commander 
does not work.
• The Remote Commander batteries are dead.
c Replace them with new batteries (see page 15).
• The COMMAND ON/OFF switch is set to OFF.
c Set it to ON.
• The ID number of the projector assigned in “ID Mode” in the 
Installation menu does not match the ID number of the ID MODE 
keys on the Remote Commander.
c Assigns the same ID number to the projector and the Remote 
Commander, or set “ID Mode” in the Installation menu to “All.”
Symptom
Cause and Remedy
The control panel keys do 
not function.
The control panel keys are locked.
c Unlock the control panel keys (see page 35).
The fan is noisy.
c Check the setting of “Cooling Setting” in the Setup menu (see 
c Check the ventilation holes are not blocked.
c Make sure the room temperature is not too high.
To maintain the product reliability of the projector’s components, 
the rotation speed of the fan increases and the fan becomes 
slightly noisier, when the room temperature exceeds normal. The 
approximate normal temperature is 25°C. 
Symptom
Cause and Remedy
The LAMP/COVER 
indicator flashes in orange. 
(Repetition rate of 2 
flashes)
• The lamp cover or the air filter cover is detached.
c Attach the cover securely (see pages 41 and 42).
The LAMP/COVER 
indicator flashes in orange. 
(Repetition rate of 3 
flashes)
• The lamp has reached the end of its life.
c Replace the lamp (see page 40).
• The lamp has reached a high temperature.
c Wait for 60 seconds to cool the lamp and then turn on the power 
again.
ON/STANDBY flashes in 
red. (Repetition rate of 2 
flashes)
• The internal temperature is unusually high.
c Check to see that nothing is blocking the ventilation holes.
• The projector is being used at a high altitude.
c Ensure that “Cooling Setting” in the Setup menu is set to “On.”
ON/STANDBY flashes in 
red. (Repetition rate of 4 
flashes)
The fan is broken.
c Consult with qualified Sony personnel.
ON/STANDBY flashes in 
red. (Repetition rate of 6 
flashes)
Unplug the AC power cord from the wall outlet after the ON/
STANDBY indicator goes out, plug the power cord to the wall 
outlet, and then turn the projector on again. If the ON/STANDBY 
flashes in red and the problem persists, the electrical system has 
failed.
c Consult with qualified Sony personnel.