Nokia 6235 Service Manual

Page of 48
6235/6235i/6236i (RM-60)
Baseband Description and Troubleshooting
Page 44 
©2005 Nokia Corporation     Company Confidential
Issue 1 04/2005
3. Is System clock at 19.2MHz
4. Is Sleep Clock at 32kHz
5. If all the above checks pass, then check whether terminal is jammed or a flash 
fault exists.
Figure 47: Test Points when current too high
Terminal in Local Mode Test
):
1. Is the BSI line at X2000?
2. Is the BSI line at R2203?
3. Is the BSI line at R2206?
4. Is Sleep Clock at 32kHz?
5. Is System Clock at 19.2kHz
VBAT
BSI
GND
System Clock
Sleep Clock
X2000
R2203
R2206