5.1 Troubleshooting
244
Installation Manual
5.1.5
Troubleshooting by Error Log
When a major system error occurs in the PBX, the ALARM indicator on the front of the shelf turns on red, 
and the system logs the error information.
Error Log Display Format
Below is the display format of the error log. For information about how to view the error log using the KX-TDE Maintenance Console, refer to "2.5.8 Utility—Error Log" in the PC Programming Manual.
Example: KX-TDE Maintenance Console
Example: Station Message Detail Recording (SMDR)
Description
Item
Description
1
Date
The date of the error detection.
2
Time
The time of the error detection.
3
Level
Minor (MN ALM)
Displays minor errors, which affect only a certain part of system 
operation.
Major (MJ ALM)
Displays major errors, which affect operation of the whole 
system, or result in system failure.
4
Error Code
The 3-digit error code assigned by the PBX.
1
2
4
5
6
3
7
07/01/01 10:37AM  MJ  ALM #000 10000  MPR WDT overflow
07/01/01 11:07AM  MN ALM #010 10000  AC power down
07/01/01 03:55PM  MN ALM #301 10501  Digital trunk RAI reception