Removing and replacing the lamp unit
1. Turn the projector upside down and place it gently on a soft 
cloth.
2. Use a Phillips screw driver to loosen the 2 lamp unit fixing 
screws until the screws turn freely and remove the lamp unit 
cover.
3. Use a Phillips screw driver to loosen the 2 lamp unit fixing 
screws until the screws turn freely.
4. Hold the handle of the lamp unit and pull out gently from the 
projector.
5. Replace the new lamp unit while making sure that the 
direction of insertion is correct.
 
Press the top of the lamp unit and make sure the unit is 
installed securely.
6. Tighten the lamp unit fixing screws securely with a Phillips 
screwdriver.
7. Attach the lamp unit cover and tighten the 3 lamp unit cover 
fixing screws securely with a Phillips screw driver.
J
Resetting the LAMP RUNTIME
If the lamp usage time has passed 2 000 hours (when LAMP POWER has been set to NORMAL), the 
projector will switch to standby mode after approximately 10 minutes of operation. The resetting procedure 
should thus be completed within 10 minutes.
1. Connect the mains lead to the projector and a 
mains socket, and switch the MAIN POWER on.
2. Press the POWER button.
3. Press the MENU button to display the menu.
4. Select the OPTION menu and press the ENTER 
button.
5. Select LAMP RUNTIME.
6. Press and hold the ENTER button for 
approximately 3 seconds.
7. The confirmation screen will be displayed and 
select OK.
8. Press the POWER button to turn off for resetting 
the duration of the LAMP RUNTIME.
9. Confirm the duration of time in LAMP RUNTIME is 
reset to “0 H”.
NOTE:
• Be sure to install the lamp unit and attach the lamp unit cover securely. If they are not 
installed securely, it may cause the protection circuit to operate so that the power cannot be 
turned on.
• Grip the handle and keep the lamp unit paralleled when you remove the lamp unit. Some 
parts of the lamp unit are sharpened and may cause injury.
• Do not switch the power on while the lamp unit cover removed.
Lamp unit cover fixing screws
Lamp unit cover
Lamp unit fixing screws
Handle
Press here
Press here