Panasonic pv-c2024k User Manual

Page of 8
-6-
Basic Operation (Unit)
R E C
1 2 : 0 0 P M
C H 0 8
0 : 4 7
0 : 1 2 : 2 0
S L P
N O V - C H I P D A T A
Press POWER on remote or unit.
Use CH Ÿź or NUMBER keys to select 
a channel.
Press VOL + or VOL - to adjust volume. 
 Using 100 key
When selecting CABLE channels 100 to 125 with 
the NUMBER keys, ¿rst press 100 key, and then 
enter the remaining two digits.
 Rapid Tune
Press R-TUNE to display the last channel you were 
watching.
 Audio Mute
Press MUTE to instantly mute the sound. Press 
again to restore the previous sound level.
 Phones
Connect an earphone (not supplied) or headphones 
(not supplied) to PHONES Jack.
NIGHT Mode
Colour and picture intensity levels are adjusted so 
the screen is easier on your eyes during night time 
use.
Press NIGHT to set.
Press NIGHT to cancel.
•  Previous settings are 
restored.
•  NIGHT mode is cancelled 
when power is turned off or 
power failure occurs.
TV Operation
Selecting Input Mode
 Method 1
Press INPUT repeatedly.
Channel Number Ù LINE
1
2
3
125
LINE
(CABLE)
69
(TV)
or
Press DISPLAY to display or remove overlay.
Whenever a blank section of a tape comes up in 
Play mode, or when the selected channel has no 
broadcast signal with the Weak Signal Display set 
to “OFF”, the screen will turn solid blue.
Function Status
Current Time
Rec Time Remaining
(OTR mode only, see p. 7)
Counter
Tape Speed
Channel
VCR Status & Clock Display
Blue Screen Display
ACTION key on unit
Using ŸźŻ Ź keys
Ÿ : CH UP
ź : CH DOWN
Ź : VOLUME UP
Ż : VOLUME DOWN
Whenever the menu or program screen is 
displayed, CHANNEL UP/DOWN function as Ÿź
and VOLUME UP/DOWN function as ŻŹ only.
On Remote
On Unit
On Unit
You can operate the menu screen using unit 
buttons. To display the menu, press STOP/EJECT 
and REW together with no tape inserted. To exit the 
menu, repeat above.
STOP/EJECT REW/
ACTION
VOL
CH
Auto Operation Functions
 Auto Shut Off
No broadcast signal in TV (Only when Weak Signal 
Display is set to OFF), blank tape is played for 5 
minutes
Ö
 Power turns off 
•  This feature is cancelled if any button is pressed during 
above mode.
 Auto Playback
Insert a tape Ö Power comes on
Ö
 Play starts if there is no record tab
 Auto Rewind
Tape end Ö Rewind Ö Stop
 Playback Auto Eject
 
(Repeat Play is “OFF”)
Play Ö Tape end Ö Rewind Ö Stop
Ö
 Tape ejects if there is no record tab
1
2
C H 0 8
3
2 4
N I G H T
 Method 2
Press CH Ÿź. Display will change as below.
Note:
•  You can set the Input mode from MENU.
 MAIN MENU 
Ö
 TV 
Ö
 INPUT SELECT 
Ö
 TUNER or 
LINE
-5-
VHF/UHF
VHF/UHF
VHF/UHF
VHF/UHF
 For ANT./Cable
Connect the cable from Antenna/Cable to 
the VHF/UHF terminal on unit.
IN from 
ANT./CABLE
VHF/UHF
Please make all cable or antenna connections before power on.
Cable TV
Converter Box
Connecting
IN from 
ANT./CABLE
UNIT (rear view)
UNIT (rear view)
 For DSS/Cable Box
Connect the OUT jack on your cable box to 
the VHF/UHF terminal on unit with a RF 
cable.
VHF/UHF
CAUTION
Overtightening “Nut type” RF coaxial cables 
may damage jacks. Finger tighten only.
Connections/Initial Setup (Ready to Play)
If “AUTO CLOCK SET IS INCOMPLETE” 
appears, manually set clock. See “Manual 
Clock Set” section.
Initial Setup (Ready to Play)
Plug unit power cord into AC wall 
outlet. 
•  If you use a cable 
box, turn it on and set 
it to the Public 
Broadcasting Service 
(PBS) channel in your 
time zone. If you use 
a DSS receiver, it 
must be turned off.
Settings are made automatically. 
When setup is complete, this screen 
appears.
Press POWER on remote or unit.
Notes:
•  Function buttons are void during Initial Setup.
•  To eject a tape during Auto Set, press EJECT on 
remote. Then make settings manually. (See p11.)
•  If Auto Clock Set takes more than 30 minutes, press 
STOP and perform settings manually. (See  p11.)
Manual Clock Set
If AUTO CLOCK SET was incomplete.
Press ACTION on remote to display 
SET CLOCK menu.
Press Ÿź to select the month and 
Ź to set. In the same manner, 
select and set the date, year, time, 
and DST. (Daylight Saving Time)
Press ACTION to start clock and 
exit.
Reset all unit Memory Functions
Returns to factory setting. Use if relocating 
unit, or if Initial Setup needs to be redone.
• Make sure a tape is not inserted in unit.
Turn unit Power on.
Press and hold both PLAY/REPEAT 
and FF on unit for more than 5 
seconds.
• The power will shut off.
•  Please ignore “NO CASSETTE” warning.
Do “Initial Setup” at left.
Co
ng
ra
tu
la
ti
on
s
Lo
ading
 th
Ba
tter
ie
s
He
ad
 C
le
an
in
g
Fe
at
ur
es
 fo
r a 
Qua
lit
y P
icture
Reco
rd
/P
la
yback
 
Ti
m
e
DS
T (
D
ay
lig
ht
 
Sa
ving
 Ti
m
e)
Acces
so
rie
s
Preven
Acci
de
nt
al T
ape
 
Eras
ure
Speci
À
ca
tion
s
C
on
ne
ct
in
g
In
iti
al S
et
up
 
(R
ea
dy
 t
o P
la
y)
M
an
ual
 C
lo
ck
 S
et
R
es
et
 all
 u
nit
 
Me
m
or
Fu
nc
tio
ns
1
2
C H A U T O S E T P R O C E E D I N G
A U T O C L O C K S E T
P R O C E E D I N G
C A N C E L : S T O P
4
1 / 4 / 2 0 0 4 S U N 1 2 : 0 0 P M
D S T : O N
S E T T I N G :
C H
A U T O C L O C K S E T
C O M P L E T E D
A U T O C L O C K S E T
I S I N C O M P L E T E
P L E A S E S E T C L O C K B Y
P R E S S I N G A C T I O N K E Y
1
S E T C L O C K
1 / 1 / 2 0 0 4 T H U 1 2 : 0 0 A M
D S T : O N
- - - - - - - - - - - - - - - - - - - - - - -
S E L E C T :
S E T :
E N D
: A C T I O N
2
S E T C L O C K
1 / 4 / 2 0 0 4 S U N 1 2 : 0 0 A M
D S T : O N
- - - - - - - - - - - - - - - - - - - - - - -
S E L E C T :
S E T :
S T A R T : A C T I O N
3
1
2
3
Auto channel and clock set starts.
3
S E L E C T L A N G U A G E
P R E S S
C H
: E n g l i s h
A P P U Y E R C H
: F r a n ç a i s
O P R I M I R V O L + : E s p a ñ o l
Press CH Ÿ to select 
English.
Or
Press CH ź to select 
French (Français).
Or
Press VOL+ to select 
Spanish (Español).
Note to CABLE System Installer
This reminder is provided to call the CABLE 
(Cable TV) System Installers attention to 
Article 820-40 of the NEC that provides 
guidelines for proper grounding and, in 
par ticular, speci¿es that the cable ground 
shall be con nect ed to the grounding system 
of the building, as close to the point of cable 
entry as practical.
-4-
Head Clog Sensor
Screen-left appears during 
play if clogging is detected. 
To remove screen, press 
PLAY.
Congratulations
• Date of Purchase
• Dealer Purchased From
• Dealer Address
• Dealer Phone No.
• Model No.
• Serial No.
Accessories
Battery replacement caution
•  Do not mix old and new batteries.
•  Do not mix alkaline with manganese batteries.
Break off the tab to 
prevent recording.
Record 
Tab 
Screwdriver
To record again.
Cover the hole with 
cellophane tape. 
Loading the Batteries
Prevent Accidental Tape Erasure
 Remote Control
 Batteries 2 “AA”
On your new purchase! With proper use, this 
dependable product will provide years of 
enjoyment. Please ¿ll in the information below. 
(Serial number is on tag on back of unit.)
EUR7723010
Old or damaged tapes may clog heads.
Head Cleaning
Record/Playback Time
Only use tapes with the 
 mark in this unit.
Digital Auto Tracking
Continuously analyses the signal and adjusts for 
optimum picture quality.
Manual Tracking Control (to reduce picture noise)
Use during Playback and Slow Motion mode to 
reduce picture noise. Press the 3 or 6 number key on 
the remote control or CH Ÿź on the unit until the 
picture clears up. To return to Auto Tracking, press 
POWER off, then on again a few seconds later.
Features for a Quality Picture
Tape Speed 
Setting 
Type of Video Cassette 
T120
T160
T180
SP
(Standard 
Play)
2 Hours
2 Hours 40 
Minutes
3 Hours
SLP
(Super Long 
Play)
6  Hours
8  Hours
9  Hours
• Use “dry” type head cleaning cassette only.
  (Part No. NV-TCL30PT is recommended.)
• Follow cleaning tape instructions carefully. 
Excessive use of tape can shorten head life.
Unit auto adjusts clock for DST.
DST (Daylight Saving Time)
  Spring (First Sunday in April)
DST: ON Ö Sets clock ahead one hour.
  Autumn (Last Sunday in October)
DST: ON Ö Turns clock back one hour.
•  If your area does not observe Daylight Saving Time, 
select DST: OFF.
•  Keep these time changes in mind when programming 
unit for timer recordings.
V I D E O H E A D S M A Y
N E E D C L E A N I N G
P L E A S E I N S E R T H E A D
C L E A N I N G C A S S E T T E
O R R E F E R T O M A N U A L
E N D : P L A Y
Before Using
Speci¿cations
Note:
•  Designs and spec i¿ca tions are sub ject to change without 
no tice.
Display
Picture Tube
•  13 inch measured diagonal 90° 
deÀection Picture Tube 
(PV-C1324-K/ PV-C1334W-K)
•  20 inch measured diagonal 90° 
deÀection Picture Tube 
(PV-C2024-K)
VCR
Video Recording 
System
2 rotary heads helical scanning 
system 
Audio Track
1 track
Tuner
Broad cast Channels
VHF 2 ~ 13, UHF 14 ~ 69
CA BLE Channels
Midband A through I (14 ~ 22) 
Superband J through W (23 ~ 36) 
Hyperband AA ~ EEE (37 ~ 64) 
Lowband A-5 ~ A-1 (95 ~ 99) 
Special CABLE chan nel 5A(01) 
Ultraband 65 ~ 94, 100 ~ 125
General
Power Source
120 V AC, 60 Hz
Power 
Consumption
Power 
On
•  Approx. 69 W (PV-C1324-K/ 
PV-C1334W-K)
• Approx. 110 W (PV-C2024-K)
Power 
Off 
Approx. 2.5 W
Television System
EIA Standard NTSC colour
Speak er
1 pieces
Op erat ing 
Temperature
5 °C ~ 40 °C (41 °F ~ 104 °F)
Operating Humidity
10 % ~ 75 %
Weight
• 12 Kg (26.4 lbs.) (PV-C1324-K/ 
PV-C1334W-K)
• 23 Kg (50.6 lbs.) (PV-C2024-K)
Di men sions
(W X H X D)
• 386 mm (15-3/16Ǝ) X 385 mm 
(15-3/16Ǝ) X 374 mm (14-3/4Ǝ)
(PV-C1324-K/ PV-C1334W)
• 515 mm (20-5/16Ǝ) X 505 mm 
(19-7/8Ǝ) X 474 mm (18-11/16Ǝ)
(PV-C2024-K)
-3-
Safety Precautions
This symbol warns the user that uninsulated voltage 
within the unit may have suf¿cient magnitude to cause 
electric shock. Therefore, it is dangerous to make any 
kind of contact with any inside part of this unit.
#!54)/.
/&
2%-/6%
./
).3)$%
15!,)&)%$
2)3+
$/
#!54)/.
This video recorder, equipped with the HQ (High Quality) System, is compatible with existing VHS 
equipment. Only use those tapes with the 
 mark. It is recommended that only cassette tapes 
that have been tested and inspected for use in 2, 4, 6, and 8 hour VCR machines be used. This 
television receiver provides display of television closed captioning in accordance with §15.119 of 
the FCC rules. 
Im
p
o
rt
an
t Saf
e
g
u
ar
ds
 an
d
 P
re
 ca
u
 ti
o
n
s
S
af
e
ty
 P
re
c
au
ti
o
n
s
TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS 
EQUIPMENT TO RAIN OR MOIS TURE.
WARNING
CAUTION
TO PREVENT ELECTRIC SHOCK, MATCH WIDE BLADE OF PLUG 
TO WIDE SLOT, FULLY INSERT.
This symbol alerts the user that important literature 
concerning the operation and main tenance of this unit 
has been included. Therefore, it should be read carefully 
in order to avoid any problems.
-2-
OUTDOOR ANTENNA INSTALLATION
USING THE UNIT
INSTALLATION
1   POWER SOURCE CAUTION
Operate only from power source indicated on unit 
or in this manual. If uncertain, have your Electric 
Utility Service Company or Video Products Dealer 
verify your home power source.
2   POWER CORD PLUG
For safety, this unit has a polarized type plug (one 
wide blade), or a three-wire grounding type plug. 
Always hold the plug ¿rmly and make sure your 
hands are dry when plugging in or unplugging the 
AC power cord. Regularly remove dust, dirt, etc. on 
the plug.
POLARIZED PLUG CAUTION:
The plug ¿ts into outlet one way. If it cannot be fully 
inserted, try reversing it. If it still will not ¿t, have an 
electrician install the proper wall outlet. Do not 
tamper with the plug.
GROUNDING PLUG CAUTION:
The plug requires a three-hole grounding outlet. If 
necessary, have an electrician install the proper 
outlet. Do not tamper with the plug.
3   POWER CORD
To avoid unit malfunction, and to protect against 
electrical shock, ¿re or personal injury:
-  Keep power cord away from heating appliances and 
walking traf¿c. Do not rest heavy objects on, or roll such 
objects over the power cord.
-  Do not tamper with the cord in any way.
-  An extension cord should have the same type plug 
(polarized or grounding) and must be securely 
connected.
-  Overloaded wall outlets or extension cords are ¿re 
hazards.
-  Frayed cords, damaged plugs, and damaged or cracked 
wire insulation are hazardous and should be replaced by 
a quali¿ed electrician.
4  DO NOT BLOCK VENTILATION HOLES
Ventilation openings in the cabinet release heat 
generated during operation. If blocked, heat 
build-up may result in a ¿re hazard or heat damage 
to cassettes.
For your protection:
a.  Never cover ventilation slots while unit is ON, or 
operate unit while placed on a bed, sofa, rug, or 
other soft surface.
b.  Avoid built-in installation, such as a book case 
or rack, unless properly ventilated.
5  AVOID EXTREMELY HOT LOCATIONS 
OR SUDDEN TEMPERATURE CHANG ES
Do not place unit over or near a heater or ra di ator, 
in di rect sunlight, etc. If unit is sud denly moved 
from a cold place to a warm place, mois ture may 
condense in unit and on the tape caus ing damage.
6  TO AVOID PERSONAL INJURY
•  Never place unit on support or stand 
that is not ¿rm, level, and adequately 
strong. The unit could fall causing 
serious injury to a child or adult and 
damage to the unit.
•  Move any appliance and cart 
combination with care. Quick stops, 
excessive force, and uneven surfaces 
may cause objects to overturn.
•  Carefully follow all operating 
instructions.
Before unit is brought out of storage or moved to a 
new location, refer again to the INSTALLATION 
section of these safe guards.
1   KEEP UNIT WELL AWAY FROM WATER 
OR MOISTURE, such as vases, sinks, 
tubs, etc.
2   IF EXPOSED TO RAIN, MOISTURE, OR 
STRONG IMPACT, unplug unit and have it 
inspected by a quali¿ed service technician 
before use.
3   ELECTRICAL STORMS
During a lightning storm, or before leaving unit 
unused for extended periods of time, disconnect all 
equipment from the power source as well as the 
antenna and cable system.
4   WHEN UNIT IS PLUGGED IN
•  DO NOT OPERATE IF:
-  liquid has spilled into unit.
-  unit was dropped or otherwise damaged.
-  unit emits smoke, malodors, or noises.
  Immediately unplug unit, and have it inspected by a 
service technician to avoid potential ¿re and shock 
hazards.
•  Never drop or push any object through openings in unit. 
Touching internal parts may cause electric shock or ¿re 
hazard.
•  Keep magnetic objects, such as speakers, away from 
unit to avoid electrical interference.
5   USING ACCESSORIES
Use only accessories recommended by the 
manufacturer to avoid risk of ¿re, shock, or other 
hazards.
6 CLEANING UNIT
Unplug unit. Use a clean, dry, chemically untreated 
cloth to gently remove dust or debris. DO NOT USE 
cleaning Àuids, aerosols, or forced air that could 
over-spray, or seep into unit and cause electrical 
shock. Any substance, such as wax, adhesive tape, 
etc. may mar the cabinet surface. Exposure to 
greasy, humid, or dusty areas may adversely affect 
internal parts.
SERVICE
1  DO NOT SERVICE PRODUCT 
YOURSELF
If, after carefully following detailed operating 
instruc tions, the unit does not operate properly, do 
not attempt to open or remove covers, or make any 
adjustments not described in the manual. Unplug 
unit and contact a quali¿ed service tech nician.
2  REPLACEMENT OF PARTS
Make sure the service technician uses only parts 
speci¿ed by the manufacturer, or have equal safety 
char ac ter istics as original parts. The use of 
unauthorized substitutes may result in ¿re, electric 
shock, or other hazards.
3  SAFETY CHECK AFTER SERVICING
After unit is serviced or repaired, request that a 
through safety check be done as described in the 
manufacturer’s service literature to ensure video 
unit is in safe operating condition.
TO REDUCE THE RISK OF ELECTRIC SHOCK, FIRE, INJURY TO PERSONS OR 
DAMAGE TO THIS PRODUCT, READ AND RETAIN ALL SAFETY AND OPERATING 
INSTRUCTIONS. HEED ALL WARNINGS IN THE MANUAL AND ON THE PRODUCT.
WARNING
IMPORTANT SAFEGUARDS AND PRE CAU TIONS
1  SAFE ANTENNA AND CABLE 
CONNECTION
An outside antenna or cable system must be 
properly grounded to provide some protection 
against built up static charges and voltage. Section 
810 of the National Electrical Code,  ANSI/NFPA 
70 (in Canada, part 1 of the Canadian Electrical 
Code) provides information regarding proper 
grounding of the mast and supporting structure, 
grounding of the lead-in wire to an antenna 
discharge unit, size of grounding conductors, 
location of antenna discharge unit, con nec tion to 
grounding electrodes, and requirements for the 
grounding electrode.
2   KEEP ANTENNA CLEAR OF HIGH 
VOLTAGE POWER LINES OR CIRCUITS
Locate an outside antenna system well away from 
power lines and electric light or power circuits so it 
will never touch these power sources should it ever 
fall. When installing antenna, absolutely never 
touch power lines, circuits or other power sources 
as this could be fatal.
GROUND
CLAMP
ELECTRIC
SERVICE
EQUIPMENT
ANTENNA LEAD 
IN WIRE
ANTENNA
DISCHARGE UNIT
(NEC SECTION 810-20)
GROUNDING
CONDUCTORS
(NEC SECTION 810-21)
GROUND CLAMPS
POWER SERVICE 
GROUNDING
ELECTRODE SYSTEM
(NEC ART 250, PART H)
NEC - NATIONAL 
  ELECTRICAL CODE
-7-
Playback a Tape
Record tab
1
Insert a tape.
•  Unit power comes 
on automatically.
• Loose or peeling 
labels may cause 
tape jam.
2
Press PLAY.
•  Playback begins if 
tape has no record 
tab.
Basic Operation (Tape)
TV
 
Oper
at
io
n
VC
R
 S
ta
tu
s &
 
Cl
oc
k
 D
is
pl
ay
Bl
u
e S
creen
 
Dis
pl
ay
Aut
o O
p
er
at
io
Fu
n
ct
io
n
s
NI
G
H
T
 M
od
e
Sel
ecting
 
In
pu
t M
od
e
AC
T
IO
N
 
k
ey o
n
  
uni
t
Us
in
gʆʈ
ʉ
ʇ
key
s
P
lay
ba
ck
 a Tap
e
T
im
er
 
Reco
rd
in
g
Reco
rd
 On
 a
 T
ape
Rev
iew
, Re
pl
ace
 o
Cle
ar
 P
rog
ra
m
 
Co
n
te
n
ts
C
anc
el a T
ime
Reco
rd
in
g
Record On a Tape
Note:
•  After 5 minutes in Pause mode, unit stops to protect 
the tape and the video heads.
  One Touch Recording (OTR)
Press REC repeatedly to set length as follows:
30 min. Ö 1 hr. Ö 1:30 Ö 2:00 Ö 3:00 Ö 4:00 
Ö
 exit
 To Replace program...
 To Clear program...
Cancel a Timer Recording
Press ADD/DLT.
Review, Replace or Clear Program Contents
Today’s 
Date
Example
DAILY
7
2
1
31
6
8    9
SELECT     /      Selection Order
WEEKLY
(SAT)
WEEKLY
(MON)
WEEKLY
(SUN)
Notes:
•  2 minutes before Timer recording is performed, 
“PLEASE PREPARE FOR TIMER REC” appears 
and/or the PROG TIMER Indicator Àashes. Be sure 
a cassette with record tab is loaded and the unit is 
in Stop mode.
•  If there is a power interruption of more than one 
minute, the recording may not be performed or 
continued.
Hold down STOP for a few seconds to cancel 
the Timer Recording.
•  Any future daily or weekly recordings will be 
performed as programmed.
(Recording is not in progress)
(Recording is in progress)
Timer Recording
1
Press PROG to display SET 
PROGRAM screen.
2
Press Ÿź to select TIMER PROGRAMMING.
S E T P R O G R A M
T I M E R P R O G R A M M I N G
O N T I M E R
S E L E C T :
S E T :
E N D
: P R O G
3
Press Ź to display screen.
P D T
S T A R T S T O P
C H S P D
1
- - - - : - - - - : - -
- -
- -
2 - - - - : - - - - : - -
- -
- -
3 - - - - : - - - - : - -
- -
- -
4 - - - - : - - - - : - -
- -
- -
S E L E C T :
S E T :
E N D
: P R O G
4
5
Press PROG to end the program.
To Enter More Programs, press Ÿź to 
select and Ź to set an unused 
program. Then repeat step 4.
P D T
S T A R T S T O P
C H S P D
1
1 0
9 : 0 0 a 1 2 : 0 0 p 0 8
S P
2 - - - - : - - - - : - -
- -
- -
3 - - - - : - - - - : - -
- -
- -
4 - - - - : - - - - : - -
- -
- -
S E T C O M P L E T E D
C A N C E L : A D D / D L T
S E L E C T :
S E T :
E N D
: P R O G
6
Press PROG twice to exit this mode.
•  If you’re using a cable box, make sure that it is 
tuned to the desired channel and the power is 
left on for timer recording.
•  PROG TIMER indicator lights on unit.
1
Insert a tape with record tab.
•  The unit power comes on automatically.
2
Press CH Ÿź or NUMBER keys to 
select a channel.
•  For “LINE” input, see p. 6.
3
4
Press REC to start recording.
•  To edit, press PAUSE/SLOW to pause, and 
again to resume recording.
5
Press STOP to stop recording.
1
Repeat steps 1~3 at left.
2
Press Ÿź to select the desired 
program.
P D T
S T A R T S T O P
C H S P D
1
1 0
9 : 0 0 a 1 2 : 0 0 p 0 8
S P
2 d a y 1 1 : 0 0 a 1 1 : 3 0 a 1 2 5 S L P
3 1 2
8 : 0 0 p 9 : 3 0 p
L
S P
4 - - - - : - - - - : - -
- -
- -
C A N C E L : A D D / D L T
S E L E C T :
S E T :
E N D
: P R O G
P D T
S T A R T S T O P
C H S P D
1 1 0
9 : 0 0 a 1 2 : 0 0 p 0 8
S P
2 d a y 1 1 : 0 0 a 1 1 : 3 0 a 1 2 5 S L P
3 1 2
8 : 0 0 p 9 : 3 0 p
L
S P
4 - - - - : - - - - : - -
- -
- -
S E L E C T :
S E T :
E X I T
: P R O G
P D T
S T A R T S T O P
C H S P D
1
- - - - : - - - - : - -
- -
- -
2 d a y 1 1 : 0 0 a 1 1 : 3 0 a 1 2 5 S L P
3 1 2
8 : 0 0 p 9 : 3 0 p
L
S P
4 - - - - : - - - - : - -
- -
- -
S E L E C T :
S E T :
E N D
: P R O G
3
Press PROG twice to exit this 
mode.
•  1~31 = One time
•  DAILY = Mon,~Fri.
•  WEEKLY = Same time 
each week
1) Press Ź.
2) Set record DATE, 
press Ÿź to select:
3) Set remaining items, 
press Ź to set 
START / STOP times, 
Channel or LINE, and 
tape speed. Then 
press Ÿź to select.
Press SPEED to select recording 
speed. (P. 4)
1) Press Ź.
2) Repeat step 4 
(at left) to set 
new programs.
3) Press PROG.
  Press REW to rewind tape
  Press FF to fast forward tape
 Press EJECT on remote or 
STOP/EJECT on unit to eject tape
  Press FF to forward scene search
  Press REW to reverse scene search
Notes:
•  After search has begun, each additional press of 
FF or REW changes speed.
•  FF and REW search speed may vary depending 
on current tape position.
•  After 10 minutes in search mode, unit returns to 
Play mode to protect the tape and the video 
heads.
3
Press STOP.
Notes:
•  These features work best in SLP mode.
•  After 3 minutes in Still or Slow mode, unit stops to 
protect the tape and the video heads.
■ Press PAUSE/SLOW to still (freeze) picture
 Hold down PAUSE/SLOW in Still 
mode to slow motion picture
Ö
  Press PLAY to release.