Panasonic WJ-HD200 User Manual

Page of 94
36
Notes: 
• VMD should be used when the input to the unit is
from an ordinary camera. Select [OFF] to avoid use-
less VMD when a video multiplexer or combination
camera supplies the input to the unit.
• Set ALARM SUSPEND to ON when you do not want
VMD to be activated during the VMD setup.
• There may be cases where VMD does not suffi-
ciently detect changes, since it detects the
changes in luminance.
• The detection area may include areas slightly out-
side the border.
• The buzzer will beep if detection takes place during
the area setup.
4. Set the upper-left end of the detection area. Move the
asterisk to the right or left with the JogDial, and up or
down by pressing the [D] or [C] button.
5. Press the JogDial to enter the upper-left end of the
detection area. The asterisk position is highlighted.
6. Set the bottom-right end of the detection area similar to
steps 3 and 4 above.
7. Press the JogDial. The area is highlighted.
Up to 4 areas can be selected. These may partially
overlap. Repeat steps 3 to 6 to select more areas. To
deselect an area, move the cursor to the upper-left end
of the area, and press the JogDial.
■ Communication Setup
(COMMUNICATION SETUP)
Communication parameters are set to match those of the
connected devices and the system configuration. The serial
port setup and network setup are made.
■ Serial Port Setup 
(SERIAL PORT SETUP)
The SERIAL PORT SETUP menu appears when it is select-
ed in the COMMUNICATION SETUP menu.
Note: Parameters marked with * on the following pages are
default settings applicable to RS-232C.
● Protocol (PROTOCOL)
1. Move the cursor to PROTOCOL with the [D] or [C] but-
ton.
2. Select a suitable protocol with the JogDial, and press
the JogDial. 
The default is PS
DATA.
PS
DATA: Select when the communication chain uses
the PS
DATA protocol.
This selection enables the DATA terminal on the
rear panel for communication.
RS-232C: Select when a protocol other than PS
DATA
is used. 
This selection enables the RS-232C terminal on the
rear panel for communication.
Note: Parallel use of the DATA and RS-232C terminals
is not possible.
               *
CAM1
PUSH
  •  
PAUSE
/
/
SET
REW/FF
/
STEP
/
q
w
e
r
   SERIAL PORT SETUP
PROTOCOL      PS•DATA
BAUD RATE     9600
DATA BIT      8
PARITY CHECK  NONE
STOP BIT      1
WAIT TIME     OFF
CTL-UNIT ADDR 1
SYS-UNIT ADDR 1
ALARM DATA    1S
CAM NO.SETUP
O
  COMMUNICATION SETUP
SERIAL PORT SETUP
O
NETWORK SETUP
O