Mounting the Lens
Caution:
Before you mount the lens, loosen the screw on the side of the camera, and rotate the
frange-back adjusting ring clockwise until it stops.  If the ring is not at the end, the inner
glass or CCD image sensor may be
damaged.
1. Mount the lens by turning it clockwise
on the lens mount of the camera.
2. Connect the lens cable to the auto iris
lens connector on the side of the cam-
era.
Caution for Mounting the Lens
The lens mount should be a CS-mount (1”-32UN) and the lens weight should be less than
450 
g (0.99 lbs).  If the lens is heavier, both the lens and camera should be secured by
using the supporter.
The protrusion at the rear of the lens should be as shown below:
CS-mount: Less than 8 mm (5/16”)
The following adjustment should be made by qualified service personnel or system
installers.
1. Loosen the screw on the side of the
camera.
2. Turn the flange-back adjusting ring to
the desired position.
Caution:
Do not rotate the ring coun-
terclockwise by force after it stops.
If the ring is rotated by force, the
inner lens or CCD image sensor
may be damaged.
3. Tighten the screw on the side of the
camera.
Cautions:
• Tightening the screw by force will cause damage to the screw or deviation of
focus.
• To use the C-mount lens, the Lens Mount Converter (C-mount adapter) WV-AD20
should be used with the camera.
FOCUS OR FLANGE-BACK ADJUSTMENT
ALC Connector
Screw
Flange-back
Adjusting Ring
Flange-back
Adjusting Ring
Screw
CONNECTIONS
Caution:
Keep the POWER switch of the specified monitor, Camera Extension Unit and
Camera Drive Unit in OFF position while making connections. If the power of these units
is ON during connections, the camera does not function due to the built-in protection
circuit which protects it against wrong connections.
Basic System
Connect the coaxial cables between the camera and CAMERA IN connector of the
specified monitor or Camera Drive Unit. The approximate maximum cable length is as
follows:
Coaxial
Maximum
DC R/300 m (1 000 ft) of
Cable Type
Cable Length
Inner Conductor
RG-59/U
200 m (660 ft)
Less than 30 
Ω
RG-6/U
500 m (1 650 ft)
Less than 12 
Ω
The maximum DC resistance between the camera and these unit is 20 
Ω
.
Super Dynamic
Super Dynamic
Super Dynamic
Super Dynamic
Colour Monitor 
WV-CM143 
(Rear Panel)
Coaxial Cable
Coaxial Cable
Coaxial Cable
Coaxial Cable
Cameras
4
3
2
1
CAMERA INPUT
VIDEO OUT  VIDEO IN
AUDIO OUT AUDIO IN
OUT
TIMING SELECT
IN
REMOTE OUT
ALARM
CONTROL
SPOT MONITOR CONTROL IN
4
3
2
1
RESET
GND
ALL
MODE
STDBY
4
3
2
1
GND
RECOVER
CAMERA
EXTENSION IN
FOCUS
CAMERA  POWER
ON
OFF