Toshiba lf546 User Manual

Page of 157
 
 
 145 − 
 
6 F 8 A 0 9 3 4  
15. Specifications 
15.1 Flowmeter Specifications 
 
„  Overall Specifications 
Measurement range in terms of flow velocity: 
      0–0.5 m/s to 0–10 m/s 
System accuracy:    when fluid conductivity is 0.1
μS/cm or more 
 
 
Accuracy 
Flow rate as a 
percentage of range 
Span 0.5 to less than 1m/s 
Span 1.0 to 10 m/s 
0 to less than 50% 
±0.25%FS 
50 to 100% 
± 0.5%FS 
±0.5% of rate 
Note: 
The accuracy above is measured under standard operating conditions at Toshiba's 
calibration facility. 
Fluid conductivity:   
0.01 µS/cm minimum 
Measurable fluid velocity: 
 
0
1
2
3
4
5
6
7
8
9
10
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
1
導電率 μS/cm
流速 m/s
 
Fluid temperature:   
–10 to +120 °C     
Ambient temperature:  –10 to +50 °C 
Dimensions and Mass:  See Chapter 16, “Outline Dimensions.” 
 
 
Fluid conductivity (
μS/cm) 
 
Measurable fluid velocity   
(m/s) 
Meter size 
40-100mm 
Meter size 
25mm