6 F 8 A 0 9 3 4  
LF516 Detector Specifications 
 
Meter size: 
25, 40, 50, 80, 100mm 
    Fluid pressure: -0.1 ~ 2MPa 
    Connection flange standard: 
See Table 15.2 Type Specification Code 
    Heat shock resistance – 
for ceramic tube detector 
                
Cooling: ΔT ≦ 100℃/0.5s 
                Heating: ΔT ≦ 150℃/0.5s 
                      Note: Meaning that the ceramic tube detector withstands the shock of   
sudden cooling (temperature difference 100℃ or less per 0.5 seconds) 
at the cooling side. 
or sudden heating (temperature difference 150℃ or less per 0.5 seconds) 
at the heating side. 
 
    Principle materials 
Case – Stainless steel 
 
Lining – Ceramic 
 
Grounding rings – 316 stainless steel (standard) 
              See Type Specification Code for optional materials and other related information. 
 Structure: 
IP68 Watertight 
 Coating: 