Lenovo storage array 8332 User Manual

Page of 44
7.
   
Return
 
enclosure
 
to
 
fully
 
home
 
position
 
and
 
attach
 
to
 
rack
 
using
 
captive
 
fasteners
 
on
 
front
 
flanges.
Note:
  
Rack
 
rails
 
have
 
features
 
to
 
restrict
 
complete
 
enclosure
 
withdrawal
 
while
 
still
 
allowing
 
access
 
to
 
the
 
cooling
 
fans.
 
If
 
it
 
becomes
 
necessary
 
to
 
completely
 
remove
 
the
 
system,
 
pull
 
the
 
enclosure
 
out
 
until
 
it
 
stops
 
then
 
rotate
 
the
 
latches,
 
shown
 
in
 
Figure
 
15
 
(right
 
hand
 
up,
 
left
 
hand
 
down),
 
to
 
completely
 
remove
 
the
 
enclosure
 
from
 
the
 
rack.
 
Power
 
cord
 
connection
 
CAUTION:
 
The
 
power
 
connection
 
must
 
always
 
be
 
disconnected
 
prior
 
to
 
removal
 
of
 
a
 
PSU
 
from
 
the
 
enclosure.
 
To
 
connect
 
the
 
power
 
cord,
 
do
 
the
 
following:
 
1.
   
Observe
 
all
 
safety
 
and
 
ESD
 
precautions
 
listed
 
in
 
the
 
Safety
 
and
 
Warranty
 
Guide.
 
2.
   
Attach
 
a
 
power
 
cord
 
for
 
the
 
installed
 
PSU.
 
The
 
Power
 
On
 
LED
 
(see
 
1
 
in
 
 
for
 
the
 
PSU
 
will
 
blink
 
green
 
when
 
AC
 
main
 
power
 
is
 
present.
 
The
 
Power
 
On
 
LED
 
will
 
illuminate
 
a
 
constant
 
green
 
when
 
power
 
to
 
the
 
PSU
 
is
 
turned
 
on.
   
Grounding
 
checks
 
The
 
SMC
 
-
 
Storage
 
Array
 
must
 
only
 
be
 
connected
 
to
 
a
 
power
 
source
 
that
 
has
 
a
 
safety
 
electrical
 
earth
 
connection.
 
 
CAUTION:
 
If
 
more
 
than
 
one
 
enclosure
 
is
 
installed
 
in
 
a
 
rack,
 
the
 
earth
 
connection
 
to
 
the
 
rack
 
is
 
even
 
more
 
important,
 
because
 
the
 
rack
 
will
 
have
 
a
 
high
 
“earth
 
leakage
 
current”
 
(“touch
 
current”).
 
Before
 
powering
 
on,
 
the
 
earth
 
connection
 
to
 
the
 
rack
 
must
 
be
 
checked
 
by
 
an
 
electrical
 
engineer
 
who
 
is
 
qualified
 
in
 
local
 
and
 
National
 
electrical
 
standards.
 
  
Figure
 
16.
 
Connecting
 
power
 
cords
 
Chapter
 
3.
 
Getting
 
Started
 
17