kymco mo d200 Service Manual
17
. IGNITION SYSTEM
17-5
DINK 200
RESISTANCE INSPECTION
Measure the resistance between the terminals.
Measure the resistance between the terminals.
Replace the CDI unit if the readings are not
within the specifications in the table below.
Use the
x
KΩ range for the Sanwa Tester.
Use the
x
100Ω range for the Kowa Tester.
Unit: KΩ
(+)Probe
(-)Probe
(Black/Blue) (Black/Yellow) (Green/White)
(Blue/Yellow)
(Green)
(Black/Blue)
150~280
20~30
20~30
∞
(Black/Yellow)
75~100
50~70
50~70
∞
(Green/White)
7~10
50~70
∞
(Blue/Yellow)
7~10
50~70
∞
(Green)
∞
∞
∞
∞
Different data from different supplier.
(Green/White)
(Green)
(Black/Yellow)
(Black/Blue)
(Blue/Yellow)
• Due to the semiconductor in circuit, it
is necessary to use a specified tester
for accurate testing. Use of an
improper tester in an improper range
may give false readings.
• Use a Sanwa Electric Tester (07308-
0020000) or Kowa Electric Tester
(TH-5H).
• In this table, “Needle swings then
returns” indicates that there is a
charging current applied to a condenser.
The needle will then remain at “∞ ”
unless the condenser is discharged.
*