Siemens MC35 User Manual

Page of 256
AT Command Set
 
 
 
 
 
 
 
MC35_ATC_01_V05.00 
Page 186 of 256 
15.07.2002 
 
8.2  AT^MONI  Monitor idle mode and dedicated mode 
Test command 
AT^MONI=? 
Response 
^MONI: (list of supported < period >
s) OK  
Write command 
AT^MONI[=<pe
riod>] 
This command can be used to retrieve information of the serving/dedicated cell 
automatically every n seconds. It is cancelled by any character sent to serial port 
except if autobauding is enabled (+IPR=0). Then type character ´a´ to abort. 
Note:
  
The two header lines (see below) are output after every ten data lines. 
Response 
See execute command 
Parameter 
<period> 
1 – 254   Display period in seconds
 
Execute command 
AT^MONI 
This command can be used to retrieve the cell parameters of the serving/dedicated 
cell on request
Note:
  
The length of following output lines exceeds 80 characters. Therefore a terminal 
program may draw a carriage return on a screen. However, this is not part of the 
response. 
 
Response (Examples) 
ME is not connected: 
a) ME is camping on a cell 
Serving Cell                                        I Dedicated channel 
chann rs  dBm  PLMN  LAC cell NCC BCC PWR RXLev  C1 I chann TS timAdv PWR  dBm Q ChMod 
1013  21  -71 00101 1001 0103   7   7  33  -105  33 I    No connection 
b) ME camping on a cell, but searching for a better cell (cell reselection) 
Serving Cell                                        I Dedicated channel 
chann rs  dBm  PLMN  LAC cell NCC BCC PWR RXLev  C1 I chann TS timAdv PWR  dBm Q ChMod 
1013   4 –106 00101 1001 0103   7   7  33  -105  -1 I    in Reselecting 
c) ME is not camping on a cell and could not (yet) find a suitable cell 
Serving Cell                                        I Dedicated channel 
chann rs  dBm  PLMN  LAC cell NCC BCC PWR RXLev  C1 I chann TS timAdv PWR  dBm Q ChMod 
 
ME is connected: 
Serving Cell                                        I Dedicated channel 
chann rs  dBm  PLMN  LAC cell NCC BCC PWR RXLev  C1 I chann TS timAdv PWR  dBm Q ChMod 
1013  19  -76 00101 1001 0103   7   7  33  -105  33 I 1015   1      0   5  -76 0 S_HR 
 
Parameters 
Serving Cell: 
chann 
ARFCN (Absolute Frequency Channel Number) of the BCCH carrier 
rs 
RSSI value 0 – 63 (RSSI = Received signal strength indication)  
dBm 
receiving level of the BCCH carrier in dBm 
PLMN 
PLMN ID code 
LAC  
location area code, see note below. 
cell  
cell ID, see note below. 
NCC 
PLMN colour code 
BCC 
base station colour code 
PWR 
maximal power level used on RACH channel in dBm 
RXLev  minimal receiving level (in dBm) to allow registration 
C1 
coefficient for base station selection