Siemens MC35 User Manual

Page of 256
AT Command Set
 
 
 
 
 
 
 
MC35_ATC_01_V05.00 
Page 188 of 256 
15.07.2002 
 
8.3  AT^MONP  Monitor neighbour cells 
Test command 
AT^MONP=? 
Response 
^MONP: (list of supported < period >s) OK  
 
Write command 
AT^MONP=[<period>] 
This command can be used to retrieve information of up to six neighbour 
cells automatically every n seconds. It is cancelled by any character sent 
to the serial port except if autobauding is enabled (+IPR=0). Then type 
character ´a´ to abort. 
 
Response 
See execute command 
Parameter 
<period> 
1 – 254  
Display period in seconds
 
 
Execute command 
AT^MONP 
This command can be used to obtain information of up to six neighbour 
cells on request
 
Response (Example) 
 
 
 
 
 
 
 
 
 
 
Parameter: 
Chann 
ARFCN (Absolute Frequency Channel Number) of the BCCH 
carrier 
rs  
RSSI value 0 – 63 (RSSI = Received signal strength indication) 
dBm  
Receiving level in dBm 
PLMN   PLMN ID code 
BCC  
Base Station colour code 
C1  
coefficient for base station selection 
C2  
coefficient for base station reselection 
Reference 
Siemens 
Note 
·  Cell information can be issued in the form of unsolicited result codes 
(related to <period>), or it can be queried directly using the Execute 
command AT^MONI. In the first case, the ME activates its RING line 
(Logic “1”) for one second to send the URC to the connected applica-
tion. In the second case, the RING line does not change. 
·  Due to the fact that not all necessary information of the neighbour cells 
can be decoded during a connection, there are several constraints to 
be considered: 
Only neighbour cells that have already been visible in IDLE mode 
will be further updated, as long as they are still included in the list. 
Though new neighbour cells can be added to the list (e.g. due to 
handover), their C1 and C2 parameters cannot be displayed until 
the connection is released. In this case “-“ is presented for C1 and 
C2.